wired direct-clients enable

Use this command to show (on the SmartZone GUI) the device information for wired clients that are connected directly to this switch.
Syntax
wired direct-clients enable
no wired direct-clients enable
Command Default

This command is disabled by default.

Modes

Privileged EXEC Mode

Usage Guidelines

The wired direct-clients enable command is used to display only the MAC addresses that are directly attached to the switch and ignores all the MAC addresses learned on neighboring switches through LLDP.

The no form of the command (default system setting), displays the MAC addresses that are directly attached to the switch and MAC addresses learned on the non-RUCKUS devices connected to the switch on which this command is executed.

The output will be displayed on the Wired Client page in SmartZone and in the snmpwalk/snmpbulkwalk on the wired-mac table ‘1.3.6.1.4.1.1991.1.1.3.43.1.1.1.1’. Refer to the wired client visibility table in the RUCKUS FastIron MIB Reference Guide.

Examples

The following command enables showing only the wired clients directly connected to the device.

device# configure terminal
device(config)# wired direct-clients enable
History
Release version Command history
08.0.95q, 10.0.10f This command was introduced.