pvlan mapping
pvlan mapping
vlan-id [
ethernet
stackid/slot/port
| lag
decimal ]
no pvlan mapping
vlan-id [
ethernet
stackid/slot/port
|
lag
decimal
]
PVLAN mapping is not configured.
VLAN configuration mode
Privileged EXEC
This command will map the secondary VLAN to promiscuous port or LAG. Issue this command only on primary VLAN.Secondary VLAN to be mapped should be VALID.Port or LAG with which secondary VLAN is to be mapped should be a member of Primary VLAN.
The
no form of the command removes the mapping of Secondary VLAN with promiscuous port or
LAG.
The following example shows how to configure PVLAN mapping on an Ethernet interface.
device(config)#lag ISL dynamic id 1 device(config-lag-ISL)# ports ethe 1/2/3 ethe 1/2/4 LAG ISL deployed successfully! device(config-lag-ISL)#! device(config-lag-ISL)#lag promiscuous dynamic id 2 device(config-lag-promiscuous)# ports ethe 1/2/1 ethe 1/2/2 LAG promiscuous deployed successfully! device(config-lag-promiscuous)#! device(config-lag-promiscuous)#lag wallplate-1 dynamic id 3 device(config-lag-wallplate-1)# ports ethe 1/1/1 to 1/1/4 LAG wallplate-1 deployed successfully! devoce(config-lag-wallplate-1)#! device(config-lag-wallplate-1)#lag wallplate-2 dynamic id 4 device(config-lag-wallplate-2)# ports ethe 1/1/5 to 1/1/8 LAG wallplate-2 deployed successfully!
| Release version | Command history |
|---|---|
| 08.0.61 | This command was modified to support LAG ID options. |
| 08.0.70 | This command was modified to support mapping of secondary VLAN to promiscuous port or LAG. |