pdu-rate (EFM-OAM)

Configures the number of Protocol Data Units (PDUs) to be transmitted per second by the Data Terminal Equipment (DTE).
Syntax
pdu-rate value
no pdu-rate value
Command Default

The default value is one PDU per second.

Parameters
value
Specifies the number of PDUs to be sent per second. The value range can be from 1 through 10 PDUs per second.
Modes

EFM-OAM protocol configuration mode

Usage Guidelines

If the PDU rate is configured as 10 packets per second, PDUs may not get transmitted in a timely manner according to the configured PDU rate.

The no form of the command restores the default value of one PDU per second.

Examples

The following example configures the PDU rate as 6 PDUs per second.

device(config)# link-oam
device(config-link-oam)# pdu-rate 6
History
Release version Command history
08.0.30 This command was introduced.