scale-timer

Changes the timer scale, the value used by the software to calculate all VSRP timers.
Syntax
scale-timer number
no scale-timer number
Command Default

By default, the timer scale is set to 1.

Parameters
number
Specifies the multiplier factor for the timer. The range for the timer is from 1 through 10.
Modes

Global configuration mode

Usage Guidelines

Increasing the timer scale value decreases the length of all the VSRP timers equally, without changing the ratio of one timer to another.

To achieve sub-second failover times, you can shorten the duration of all scale timers for VSRP, VRRP, and VRRP-E by adjusting the timer scale. The timer scale is a value used by the software to calculate the timers. If you increase the timer scale, each timer value is divided by the scale value. Using the timer scale to adjust timer values enables you to easily change all the timers while preserving the ratios among their values. For example, if you set the timer scale to 2, all VSRP, VRRP, and VRRP-E timer values will be divided by 2. Here is an example:

Setting the Timer Scale Values

Timer Timer scale Timer value
Hello interval 1 1 second
2 0.5 seconds
Dead interval 1 3 seconds
2 1.5 seconds
Backup Hello interval 1 60 seconds
2 30 seconds
Hold-down interval 1 3 seconds
2 1.5 seconds

The no form of the command sets the multiplier to 1.

Examples

The following example shows how to set the scale timer to 2.

device(config)# scale-timer 2