ipv6 nd ra-interval
Configures the interval at which an interface sends router advertisement messages.
Syntax
ipv6 nd ra-interval
[
range
min-interval
max-interval
|
interval
]
no ipv6 nd ra-interval
[
range
min-interval
max-interval
|
interval
]
Command Default
By default, an interface sends a router advertisement message every 200 seconds.
Parameters
- range min-interval max-interval
- Configures an interval range. The min-range-value specifies the minimum number of seconds allowed between sending unsolicited multicast router advertisements from the interface. The default is 0.33 times the max-range-value if the max-range-value is greater than or equal to 9 seconds. Otherwise, the default is the value specified by the max-range-value. The min-range-value can be a number between -3 - (.75 x max range value ). The max-range-value parameter specifies the maximum number of seconds allowed between sending unsolicited multicast router advertisements from the interface. This number can be between 4 - 1800 seconds and must be greater than the min-range-value x 1.33. The default is 600 seconds.
Modes
Interface configuration mode
Usage Guidelines
RUCKUS recommends that the interval between router advertisement transmission be less than or equal to the router lifetime value if the router is advertised as a default router.
The
no form of the command resets the interface at which an interface sends a router advertisement
message to 200 seconds.