mvrp timer
mvrp timer
join
timer-value
leave
timer-value
leave-all
timer-value
no mvrp timer
join
timer-value
leave
timer-value
leave-all
timer-value
- leave timer-value
-
Defines the time period an MVRP-enabled interface waits after receiving a leave message on the port to remove the port from the VLAN indicated in the leave message. If the interface receives a VLAN join message before the timer expires, the VLAN remains registered. Valid values range from 1000 ms through 100000000 ms. The default value is 100 ms. The leave timer should be greater than or equal to twice the join timer plus 600 ms.
- leave-all timer-value
- Defines the time interval at which a port (MVRP participant) generates LeaveAll PDUs. Valid values range from 10000 ms through 100000000 ms. The default value is 10000 ms. The leave-all timer must be comparitively greater than the leave timer value; the recommended value is at least three times the value of the leave timer.
Global configuration mode
Interface configuration mode
All timer values must be in multiples of 10, 50, or 100 ms.
The MVRP timers must be set to the same values on all the devices that are participating in MVRP.
Interface-level timer configuration takes precedence over global timer configurations.
Ruckus recommends to maintain the default timer settings for MVRP implementation unless it is necessary to change.
The
no form of the command resets the timer values to the default values.
The following example enables the MVRP timers globally.
device# configure terminal device(config)# mvrp timer join 300 leave 3000 leave-all 20000
| Release version | Command history |
|---|---|
| 08.0.90 | This command was introduced. |