save-current-values

Configures a backup to save the VSRP timer values received from the master instead of the timer values configured on the backup.
Syntax
save-current-values
no save-current-values
Command Default

By default, the backups always use the value of the timers received from the master.

Modes

VSRP VRID configuration mode

Usage Guidelines

Saving the current timer values instead of the configured ones helps ensure consistent timer usage for all the VRID devices.

The no form of the command disables saving the timer values from the master.

Examples

The following example shows how to configure a backup to save the VSRP timer values received from the master instead of the timer values configured on the backup.

device(config)# vlan 200
device(config-vlan-200)# vsrp vrid 1
device(config-vlan-200-vrid-1)# save-current-values