ignore-temp-shutdown
By default, the function is disabled.
Global configuration mode
Stack-unit configuration mode
Use the
no form of the command to re-enable shutdown based on temperature threshold. The
no form of the command disables the battleshort mode at global level and at unit level.
Either the global battleshort mode or unit-specific battleshort mode is enabled, but not both.
This command can be executed at a global level and at a unit level. If the command is enabled or disabled at global level, it applies to all the units which are part of the stack. If the command is enabled or disabled at a unit level, it applies only to that unit alone in the stack. To execute this command at a unit level, specify the unit ID at Global configuration mode.
The following example enables battleshort mode on a standalone device or globally on all stack units.
device# configure terminal device(config)# ignore-temp-shutdown Ignore temperature shutdown threshold has been enabled
| Release version | Command history |
|---|---|
| 08.0.60 | The command was introduced. |
| 08.0.61 | The command was updated to support members of an ICX 7150 stack. |