optical-monitor
optical-monitor
[ alarm-interval ]no optical-monitor
[ alarm-interval ] optical-monitor
down-port-enableno optical-monitor
down-port-enable optical-monitor
non-ruckus-optic-enable no optical-monitor
non-ruckus-optic-enableOptical transceivers are not monitored.
Global configuration mode
Interface subtype configuration mode
When Digital Optical Monitoring (DOM) is enabled, the system continuously monitors the temperature and signal power levels of the optical transceivers. If the optical operating conditions fall below or exceed the manufacturer-recommended thresholds for QSFP28, QSFP+, SFP28, SFP, or SFP+, the system generates console and syslog messages.
By default, optical monitoring is active for ports that are up. If you enable the down-port-enable option, the system also monitors ports that are down.
The system is set by default to monitor RUCKUS brand optics. To monitor non-RUCKUS optics, use the non-ruckus-optic-enable option.
This command is not supported for Link Aggregation Group (LAG) interfaces.
The following example enables optical monitoring on all RUCKUS-qualified optics installed in the device.
device# configure terminal device(config)# optical-monitor
The following example enables optical monitoring on a specific port.
device# configure terminal device(config)# interface ethernet 1/1/1 device(config-if-e10000-1/1/1)# optical-monitor