fdp holdtime

Configures the Foundry Discovery Protocol (FDP) update hold time.
Syntax
fdp holdtime secs
no fdp holdtime
Command Default

By default, a device that receives an FDP update holds the information until the device receives a new update or until 180 seconds have passed since receipt of the last update.

Parameters
secs
Specifies the number of seconds for which a device that receives an FDP update can hold the update before discarding it. Valid values are from 10 through 255. The default value is 180.
Modes

Global configuration mode

Usage Guidelines

Once the device receives a new update or once 180 seconds have passed since receipt of the last update, the device discards the update.

The no form of the command sets the hold time to its default value of 180 seconds.

Examples

The following example sets the FDP hold time to 200 seconds.

device(config)# fdp holdtime 200