logging enable rfc5424
Syslog is generated in accordance with RFC 3164.
Global configuration mode
The Logging buffer must be cleared before enabling Syslog specific to RFC 5424, otherwise system throws an error.
If the logging enable rfc5424
command is present in the running configuration, the logging cli-command
feature is not supported.
The
no form of the command enables Syslog logging in accordance with RFC 3164.
The following example enables Syslog logging in accordance with RFC 5424.
device(config)# clear logging device(config)# logging enable rfc5424
| Release version | Command history |
|---|---|
| 08.0.40 | This command was introduced. |
| 08.0.30h | Support for the command was added. |