inline power adjust class
inline power adjust classr
class
{
delta
milliwatts
|
minimum
milliwatts
}
no inline power adjust classr
class
{
delta
milliwatts
|
minimum
milliwatts
}
Global configuration mode
These configurations should be used only when ports are entering an overload condition because of faulty PDs that are requesting lower power through LLDP/CDP messages and then consuming higher than the requested power.
The delta option assures the power allocation is equal to LLDP/CDP requested power plus delta power that is configured for that PD class.
The minimum option assures that the power allocation is equal to the maximum of LLDP/CDP power requested and the minimum power configured for that PD class.
Given a configuration of
inline power adjust class 1
delta
800. If a class 1 PD is connected and is requesting power of 2600 milliWatts through
LLDP/CDP, then the total allocation from the switch would be 3200 milliWatts. But
if a class 2 PD is connected then there won't be any extra power allocation. If you
want the extra power allocation for a class 2 PD, the configuration would be
inline power adjust class 2
delta 800.
Set the detected PD class to 1 and allocate 800 milliwatts of extra power for the class.
device(config)# inline power adjust class 1 delta 800
| Release | Command History |
|---|---|
| 08.0.30f | This command was introduced. |