Configures the log facility to log messages from the device.
Syntax
logging facility
facility-name
Command Default
The default facility for messages that the device sends to the syslog server is "user".
Parameters
- facility-name
- Specifies the facility to log the messages from the device. The facility name can
be one of the following:
- auth
- Security or authorization messages.
- local0
- Reserved for local use.
- local1
- Reserved for local use.
- local2
- Reserved for local use.
- local3
- Reserved for local use.
- local4
- Reserved for local use.
- local5
- Reserved for local use.
- local6
- Reserved for local use.
- local7
- Reserved for local use.
- lpr
- Line printer subsystem.
- syslog
- Messages generated internally by syslog.
- sys9
- Reserved for system use.
- sys10
- Reserved for system use.
- sys11
- Reserved for system use.
- sys12
- Reserved for system use.
- sys13
- Reserved for system use.
- sys14
- Reserved for system use.
- user
- Random user-level messages.
Modes
Global configuration mode
Usage Guidelines
The syslog daemon on the syslog server uses a facility to determine where to log the
messages from the
RUCKUS device. You can specify only one facility. If you configure the device to use two
syslog servers, the device uses the same facility on both servers.
The
no form of the command restores the default facility.
Examples
The following example changes the log facility.
device(config)# logging facility local0