show power-savings-statistics
Displays the power savings statistics for the device.
Modes
User EXEC mode
Usage Guidelines
Use this command to display the Energy Efficient Ethernet (EEE) state, traffic port utilization percentage, power rating in megawatts, power consumed in megawatts, power conserved in megawatts, and the power efficiency of the system as a percentage.
This command is not supported for RUCKUS ICX 7850 and ICX 7650 devices.
Examples
The following example displays the power savings statistics for the device.
device# show power-savings-statistics
Warning - The below is a theoretical calibrated estimation, there may be +- 5% deviation on the data.
The Power statistics of the switch for the last 5 minutes is
The total power consumption of the switch for the past 5 minutes is ------------------------> 76064 milli Watts
The total power savings after enabling EEE for the past 5 minutes is ------------------------> 3598 milli Watts
The power efficiency of the Switch after Enabling EEE for the past 5 min is ------------------> 4%
The Port specific statistics for the past 5 minutes is
Port EEE-State Traffic Power_Rating Power_Consumed Power_Conserved Power_Efficiency
Port Utilization% in mW in mW in mW in%
1/1/1 Enable 0 333 7 257 77
1/1/2 Enable 0 33 76 257 77
1/1/3 Enable 0 333 76 257 77
1/1/4 Enable 0 333 76 257 77
1/1/5 Enable 0 333 76 257 77
1/1/6 Enable 0 333 76 257 77
1/1/13 Enable 0 333 76 257 77
1/1/14 Enable 0 333 76 257 77
1/1/15 Enable 0 333 76 257 77
1/1/16 Enable 0 333 76 257 77
1/1/21 Enable 0 333 76 257 77
1/1/22 Enable 0 333 76 257 77
1/1/23 Enable 0 333 76 257 77
1/1/24 Enable 0 333 76 257 77
1/2/1 Enable 0 0 0 0 0
1/2/2 Enable 0 0 0 0 0
1/2/3 Enable 0 0 0 0 0
1/2/4 Enable 0 0 0 0 0
History
| Release version | Command history |
|---|---|
| 08.0.30 | This command was introduced. |