spx interactive-setup
Privileged EXEC mode
You cannot use the
spx interactive-setup or the
zero-touch-enable command from a device running FastIron release 08.0.90 or later to discover PE candidates
running a pre-08.0.90 release, due to a difference in message types beginning with
the FastIron 08.0.90 release. Be sure to load the same FastIron 08.0.90 or later image
to the potential PE units before executing either command.
You can abort SPX interactive-setup at any time by pressing <CTRL>-C.
SPX interactive-setup will abort afer two minutes of inactivity.
You can use SPX interactive-setup for configuration that is not possible with SPX zero-touch features.
You can use SPX interactive-setup to handle invalid topologies by specifying units to form a valid topology.
If not all units are discovered when you run
spx interactive-setup, you can run the utility again.
spx interactive-setup.
device# spx interactive-setup You can abort interactive-setup at any stage by <ctrl-c> 0: quit 1: change PE IDs 2: discover and convert new units (no startup-config flash) to PEs 3: discover and convert existing/new standalone units to PEs Please type your selection:
device# configure terminal
device(config)# spx cb-enable
System is now in 802.1br control bridge (CB) mode.
device(config)# spx cb-config
device(config-spx-cb)# spx-port 1/1/3
device(config-spx-cb)# spx-port 1/1/16
device# spx interactive-setup
You can abort spx interactive-setup at any stage by <ctrl-c>
0: quit
1: change PE IDs
2: discover and convert new units (no startup-config flash) to PEs
3: discover and convert existing/new standalone units to PEs
Please type your selection: 2
Probing topology to find new units...
Horizontal bars link to discovered units. Vertical bars link to CB or PEs.
#1: icx7250-24-port-management-module CC4E.24DC.E9CE
#2: icx7250-24-port-management-module CC4E.24DC.F166
1/1/3 1/1/16
| |
| |
2/3 2/4
+----+ +----+
| 1 |2/5==2/5| 2 |
+----+ +----+
Discovered 1 chain/ring
chain #0: Do you want to select this chain?(enter 'y' or 'n'): y
#1: icx7250-24-port-management CC4E.24DC.E9CE, type an ID (No: 0, default: 17): <-- You can change
the default id,
or just type
enter to use
the default
#2: icx7250-24-port-management CC4E.24DC.F166, type an ID (No: 0, default: 18):
2 unit(s) selected: #1: ID=17, #2: ID=18,
#1 #2
+----+ +----+
1/1/3--2/3| 17 |2/5==2/5| 18 |2/4--1/1/16
+----+ +----+
Will produce the above topology. Do you accept it? (enter 'y' or 'n'): y
spx interactive-setup discovers 1 chain(s). valid #=1, selected #=1
Send reload to chain0: #1 CC4E.24DC.E9CE ID=17, D0: 2/3, D1: 2/5 to 2/6 2/8
#2 CC4E.24DC.F166 ID=18, D0: 2/5 to 2/6 2/8, D1: 2/4
Exit spx interactive-setup, reason: 1/1/3 (linking to cc4e.24dc.e9ce) down
Exit spx interactive-setup, reason: 1/1/16 (linking to cc4e.24dc.f166) down
Exit spx interactive-setup, reason: 1/1/3 (linking to cc4e.24dc.e9ce) down
Exit spx interactive-setup, reason: 1/1/16 (linking to cc4e.24dc.f166) down
U18-MSG: PS 1, Internal Power supply is up.
Sica Unit id:18, PoD License Capacity:8
Sica Unit id:17, PoD License Capacity:8
device# show spx
T=42m39.1: alone: standalone, D: dynamic cfg, S: static
ID Type Role Mac Address Pri State Comment
1 S ICX7750-48XGF alone cc4e.24d2.2c00 0 local Ready
17 D ICX7250-24 spx-pe cc4e.24dc.e9ce N/A remote Ready
18 D ICX7250-24 spx-pe cc4e.24dc.f166 N/A remote Ready
+---+
2/1| 1 |2/4
+---+
+----+ +----+
1/1/3--2/3| 17 |2/5==2/5| 18 |2/4--1/1/16
+----+ +----+
| Release version | Command history |
|---|---|
| 08.0.50 | This command was introduced. |