Configures a scale time factor that increases the timing sensitivity across all configured
and default Virtual Router Redundancy Protocol Extended (VRRP-E) timers.
A number representing the scale of the division of a VRRP-E configured interval timer
or the default interval timer. Valid values are in a range from 1 through 10. The
default value is 1.
Modes
VRRP-E router configuration mode
Usage Guidelines
Configuring the VRRP-E scale timer is supported only in VRRP-E sessions. When a scaling
value is configured, the existing timer values are divided by the scaling value. For
example: a value of 10 divides the timers by a factor of 10, allowing the default
dead interval to be set to 300 ms. Using timer scaling, VRRP-E subsecond convergence
is possible if a master VRRP device fails.
The
no form of the command restores the default.
Note: Increased timing sensitivity as a result of this configuration could cause protocol
flapping during periods of network congestion.
Examples
The following example scales all VRRP-E timers by a factor of 10.