SD-LAN Service Statistics
- On the navigation bar, select , then click the SD-LAN tile and click on a specific SD-LAN service name.
- Navigate to the Instances section
and click the RUCKUS
Edges tab. This displays the number of tunnels, number of active
APs, and number of tunneled VLANs for the configured clusters.
Note: The SD-LAN tunnel statistics are updated every 5 minutes.
Statistics for an Active-Active DC Cluster
From an SD-LAN Service details page, selecting the RUCKUS Edges tab, then clicking on a specific cluster name, displays the RUCKUS Edges sidebar containing the following information:
- RUCKUS Edge: This displays the name of the RUCKUS Edge device.
- Status: This displays the current status of the RUCKUS Edge device.
- HA Status: This displays the High Availability status.
- Active APs: This shows the number of APs currently connected to the given Data Center (DC) Edge device and have an active VxLAN-GPE tunnel with the Edge device.
- Primary APs: This shows the number of APs that have selected the given DC Edge device as their primary Edge device. The primary Edge device is the first Edge in the randomized list generated by the AP and is the preferred Edge for forming the VxLAN-GPE tunnel. If the primary Edge is not available, the AP forms a tunnel to the next available Edge in the randomized list. Therefore, the Primary APs count might differ from the Active APs count.
- L2GRE Status: Displays the number of active L2GRE tunnels from the selected Edge. Hover over L2GRE Status to view the applied L2GRE tunnel profile and the current tunnel status.
At the time of fallback, the APs fall back to the primary Edge. If all the Edge devices are available, the Active APs and Primary APs count for a given Edge will be equal.
Statistics for a DMZ Cluster
- Active SEs: This shows the number of DC Edge devices currently connected to the given DMZ Edge device. There is an active VxLAN-GPE tunnel between the number shown under Active SEs and the given DMZ Edge.
- Primary SEs: This shows the number of DC Edge devices that have the given DMZ Edge device as their Primary Edge. The Primary Edge is the first Edge in the randomized list generated by the DC Edge and is the preferred Edge for forming the VxLAN-GPE tunnel. If the Primary DMZ Edge is not available, the DC Edge forms a tunnel to the next available Edge device in the randomized list. Therefore, the Primary SEs count might differ from the Active SEs count.
At the time of fallback, the DC Edge devices fallback to the Primary Edge. In a case where all the DMZ Edge devices are available, the Active SEs and Primary SEs count for a given Edge will be equal.
SD-LAN Service-Related Events on RUCKUS One
Managed devices generate events on RUCKUS One to inform administrators about identified changes occurring on those devices. The following list outlines the supported events displayed on RUCKUS One for the SD‑LAN service.
- AP gets connected to a specified Edge over a VxLAN‑GPE tunnel
- AP gets disconnected from an Edge
- Fallback is initiated for an AP to connect to the primary Edge at the configured fallback time
- Fallback is completed when the AP connects to the primary Edge at the fallback time
- Edge drops unsupported VLAN‑1 traffic