Quarantine State
A power-on self-test (POST) failure causes the system to enter the quarantine state. In this state, only the CO, using the administrator account, can access the command-line interface (CLI) through the console to perform recovery operations. A limited set of CLI commands is available for system recovery.
In the quarantine state, all communication towards
external nodes is disabled, and network interfaces remain inactive. The output
for the
fips status
command displays the current FIPS mode and the quarantine status, as shown below.
To recover from the quarantine state, the CO must
log in to the console and execute the fips disable command, and
confirm the action by entering yes. This process cleans up the system
and recovers the CLI functionality. The CO can then use the setup command to
reconfigure the system.