Enabling SmartCell Insight Communication

If your ZoneDirector will be used as a data source for Ruckus SmartCell Insight (SCI) analytics engine, you can enable the SmartCell Insight Management feature to allow ZoneDirector to initiate communications with SCI at set 15 minute intervals. In this way, if ZoneDirector is behind a firewall or NAT device, it can still communicate with SCI without having to reconfigure your firewalls and NAT devices to allow SCI to contact the ZoneDirector.

This feature only needs to be enabled if ZoneDirector is inaccessible by SCI (e.g., ZoneDirector is behind a firewall/NAT device). Otherwise, configuration only needs to be done on SCI.

Note: This feature is compatible with SCI version 2.0 and later.
Note: Beginning in release 10.2, ZoneDirector can also send application recognition statistics to SCI for analysis, for monitoring application reports such as top applications by client count and top applications by traffic volume. You must enable Application Recognition & Control for any WLANs for which you want to report application data (Wireless LANs > Create/Edit > Advanced Options > Application Recognition & Control > Enable).
Note: SCI server version 5.1.1 and later is required to support ARC data.

To enable SmartCell Insight Management:

  1. Go to System > System Settings, and expand the Network Management section.
  2. Enable the check box next to Enable management by SmartCell Insight.
  3. Enter the following information for your SCI system:
    • URL: Enter the SCI URL (e.g., https://[SCI IP address]/pentaho/Home)
    • User Name: Enter the SCI login user name used for ZD-SCI communications.
    • Password: Enter the SCI login password used for ZD-SCI communications.
    • System ID: Enter the System ID that you used for the ZD data source on the SCI System Setup page (see SCI User Guide for details).
  4. Click Apply to save your changes.