Configuring ZoneDirector for Smart Redundancy
For management convenience, both ZoneDirectors in a Smart Redundancy deployment can
be managed via a single shared IP address.
To manage two ZoneDirector devices, three IP addresses would need to be configured:
All configuration changes are made to the active ZoneDirector and synchronized to the standby unit. The user can access the web interface from any of the three IP addresses, however not all configuration options are available from the standby device.
Note: If you will be deploying the two ZoneDirectors on different Layer 3 networks, you
must ensure that Port 443 and Port 33003 are open in any routers and firewalls located
between the two ZoneDirectors.
To enable Smart Redundancy:
- Log in to the web interface of the ZoneDirector you will initially designate as the primary unit.
- Go to > , and set a static IP address under Device IP Settings, if not already configured.
- Click Apply. You will need to log in again using the new IP address (if changed).
- On the same
>
page, locate the Smart Redundancy section.
- Enable the check box next to Enable Smart Redundancy.
- Enter the IP address of the backup unit under Peer Device IP Address. If you have configured Limited ZD Discovery under Access Points > Access Point Policies, you must identify the IP address of both ZoneDirectors that the APs should connect to when Smart Redundancy is active. If the Limited ZD Discovery and Smart Redundancy information you enter is inconsistent, a warning message will be displayed asking you to confirm. Note that Ruckus recommends using the Smart Redundancy feature instead of the Limited ZD Discovery feature whenever possible.
- Enter a Shared Secret for two-way communication between the two ZoneDirectors (up to 15 alphanumeric characters).
- Click Apply to save your changes and prompt ZoneDirector to immediately attempt to discover its peer on the network.
- If discovery is successful, the details of the peer device will be displayed to the right.
- If discovery is unsuccessful, you will be prompted to retry discovery or continue configuring the current ZoneDirector.
- Install the second ZoneDirector and complete the Setup Wizard.
- Go to > , enable and enter the primary ZoneDirector’s IP address in Peer Device IP address.
- Click
Apply. If an active ZoneDirector is discovered, the second ZoneDirector will assume the
standby state. If an active device is not discovered, you will be prompted to retry
discovery or to continue configuring the current device.
Note: If you want to use the same SSL certificate for both devices in a Smart Redundancy pair, you can back up the certificate/private key from one device and import it into the other. See Working with SSL Certificates for more information.Note: If you disable Smart Redundancy after it has been enabled, both ZoneDirectors will revert to active state, which could result in unpredictable network topologies. Therefore, Ruckus recommends first factory resetting the standby ZoneDirector before disabling Smart Redundancy.Note: If the active and standby ZoneDirector are on different IP subnets, APs need to know the IP addresses of both ZoneDirectors to quickly find the active ZoneDirector after a Smart Redundancy failover. You can do this by configuring the IP addresses of both devices on the > page. Specify one ZoneDirector as Primary, the other as Secondary. Alternatively, you can also specify the IP addresses of both ZoneDirectors using DHCP Option 43.