Quarantine State
When a power-on self-test (POST) fails, the system moves to the quarantine state. In the quarantine state, only the CO (admin) can log in to the command line interface (CLI) through console access, and recover the system, and limited CLI commands are available for system recovery.
In the quarantine state, all communication towards external nodes is disabled, and
network interfaces are down. The output for the
fips status command displays the current FIPS mode and the quarantine status, as shown in the
following figures.
To recover from the quarantine state, the CO (admin) must log in to the console and
use the
fips disable command, and enter
yes to confirm. This cleans up the system and recovers the CLI capabilities. The CO (admin)
can use the
setup command to reconfigure the system.
_5.1.1=GUID-48186947-E779-453C-80B1-E15B82264A4A=2=en-US=Low.png)