show chassis
Displays chassis information.
The
show chassis command output displays the following information.
| Output field | Description |
|---|---|
| Power supply # | The presence, status, output type, model number, serial number, and firmware version number of the power supply units, if present. |
| Power supply # Fan Air Flow Direction | The air flow direction of the power supply unit. |
| Fan # | The presence, status, speed mode, and air flow direction of the fan. The fan controlled temperature and temperature thresholds. |
| MAC # Temperature Readings | The current temperature reading of the MAC device. |
| CPU Temperature Readings | The current temperature reading of the CPU. |
| sensor # Temperature Readings | The current temperature reading of the sensor. |
| Boot Prom MAC | The MAC address of the boot prom. |
| Management MAC | The management MAC address, for the active controller only. |
Modes
Privileged EXEC mode
Examples
The following is sample output from the show chassis command
executed on an ICX 8200 device.
ICX8200-48PF2 Router# show chassis
The stack unit 1 chassis info:
Power supply 1 (AC - PoE) present, status ok
Model Number: 23-1000100-01
Vendor Serial Number: SA01A7372125000087
Firmware Ver: 32.65
Power supply 2 present, status failed, reason NO POWER INPUT
Fan 1 ok, speed (auto): [[1]]<->2
Fan 2 ok, speed (auto): [[1]]<->2
Fan controlled temperature: 35.5 deg-C
Fan speed switching temperature thresholds:
Speed 1: NM<----->56 deg-C
Speed 2: 48<-----> 69 deg-C (shutdown)
Fan 1 Air Flow Direction: Front to Back
Fan 2 Air Flow Direction: Front to Back
Slot 1 Current Temperature: 25.0 deg-C (Sensor 1), 30.0 deg-C (Sensor 2), 35.5 deg-C (Sensor 3), 37.0 deg-C (Sensor 4), 33.0 deg-C (Sensor 5)
Warning level.......: 55.0 deg-C
Shutdown level......: 69.0 deg-C
Boot Prom MAC : c0c5.207e.9cd2
Management MAC: c0c5.207e.9cd2