show chassis

Displays chassis information.
Syntax
show chassis

The show chassis command output displays the following information.

Output field Description
Power supply # The presence, status, output type, model number, serial number, and firmware version number of the power supply units, if present.
Power supply # Fan Air Flow Direction The air flow direction of the power supply unit.
Fan # The presence, status, speed mode, and air flow direction of the fan. The fan controlled temperature and temperature thresholds.
MAC # Temperature Readings The current temperature reading of the MAC device.
CPU Temperature Readings The current temperature reading of the CPU.
sensor # Temperature Readings The current temperature reading of the sensor.
Boot Prom MAC The MAC address of the boot prom.
Management MAC The management MAC address, for the active controller only.
Modes

Privileged EXEC mode

Examples

The following is sample output from the show chassis command executed on ICX 7150-24P, ICX 7150-48P, or ICX 7150-48PF devices.

device# show chassis

The stack unit 1 chassis info: 

Power supply 1 (AC - PoE) present, status ok

Fan 1 ok, speed (auto): [[1]]<->2                                 
Fan 2 ok, speed (auto): [[1]]<->2

Fan controlled temperature: 
        Rule 1/2 (MGMT THERMAL PLANE): 43.2 deg-C
        Rule 2/2 (AIR OUTLET NEAR PSU): 28.0 deg-C

Fan speed switching temperature thresholds:
        Rule 1/2 (MGMT THERMAL PLANE):
                Speed 1: NM<-----> 70       deg-C
                Speed 2:        60<----->105 deg-C (shutdown)
        Rule 2/2 (AIR OUTLET NEAR PSU):
                Speed 1: NM<-----> 58       deg-C
                Speed 2:        49<----->105 deg-C (shutdown)

Fan 1 Air Flow Direction:Front to Back
Fan 2 Air Flow Direction:Front to Back
Slot 1 Current Temperature: 43.7 deg-C (Sensor 1), 43.2 deg-C (Sensor 2), 28.0 deg-C (Sensor 3), 36.3 deg-C (Sensor 4), 34.2 deg-C (Sensor 5)
Slot 2 Current Temperature: NA
Slot 3 Current Temperature: NA
        Warning level.......: 100.0 deg-C
        Shutdown level......: 105.0 deg-C
Boot Prom MAC : 609c.9ffc.3b7c

The following is sample output from the show chassis command executed on an ICX 7150-48ZP device.

device# show chassis

The stack unit 1 chassis info: 

Power supply 1 present, status failed, reason NO AC POWER INPUT
Power supply 2 (AC - PoE) present, status ok
        Model Number:   YM-1921AB06R
        Serial Number:  SA000V171708000163
        Firmware Ver:   P2H802A00
Power supply 2 Fan Air Flow Direction:  Front to Back

Fan 1 ok, speed (auto): [[1]]<->2
Fan 2 ok, speed (auto): [[1]]<->2

Fan controlled temperature: 
        Rule 1/3 (MGMT THERMAL PLANE): 35.9 deg-C
        Rule 2/3 (PoE THERMAL SENSOR PLANE): 35.0 deg-C
        Rule 3/3 (MISC THERMAL PLANE): 51.0 deg-C

Fan speed switching temperature thresholds:
        Rule 1/3 (MGMT THERMAL PLANE):
                Speed 1: NM<-----> 95       deg-C
                Speed 2:        85<----->105 deg-C (shutdown)
        Rule 2/3 (PoE THERMAL SENSOR PLANE):
                Speed 1: NM<----->130       deg-C
                Speed 2:       120<----->130 deg-C                
        Rule 3/3 (MISC THERMAL PLANE):
                Speed 1: NM<----->100       deg-C
                Speed 2:        85<----->108 deg-C

Fan 1 Air Flow Direction:  Front to Back 
Fan 2 Air Flow Direction:  Front to Back 
Slot 1 Current Temperature: 33.0 deg-C (Sensor 1), 36.4 deg-C (Sensor 2), 35.0 deg-C (Sensor 3), 50.0 deg-C (Sensor 4)
Slot 2 Current Temperature: NA
        Warning level.......: 102.0 deg-C
        Shutdown level......: 105.0 deg-C
Boot Prom MAC : 609c.9fe2.12ce

The following is sample output from the show chassis command executed on an ICX 8200 device.

ICX8200-48PF2 Router# show chassis
 
The stack unit 1 chassis info:
 
Power supply 1 (AC - PoE) present, status ok
        Model Number:   23-1000100-01
        Vendor Serial Number:   SA01A7372125000087
        Firmware Ver:   32.65
Power supply 2 present, status failed, reason NO POWER INPUT
 
Fan 1 ok, speed (auto): [[1]]<->2
Fan 2 ok, speed (auto): [[1]]<->2
 
Fan controlled temperature: 35.5 deg-C
 
Fan speed switching temperature thresholds:
                Speed 1: NM<----->56       deg-C
                Speed 2:       48<-----> 69 deg-C (shutdown)
 
Fan 1 Air Flow Direction:  Front to Back
Fan 2 Air Flow Direction:  Front to Back
Slot 1 Current Temperature: 25.0 deg-C (Sensor 1), 30.0 deg-C (Sensor 2), 35.5 deg-C (Sensor 3), 37.0 deg-C (Sensor 4), 33.0 deg-C (Sensor 5)
        Warning level.......: 55.0 deg-C
        Shutdown level......: 69.0 deg-C
Boot Prom MAC : c0c5.207e.9cd2
Management MAC: c0c5.207e.9cd2
History
Release Command History

08.0.00a

This command was enhanced to display model number, serial number, and firmware version number for power supply units.

08.0.60

The command output was enhanced to display the status of the fan as fanless mode if the mode is enabled.

08.0.80

The command output was enhanced to display the temperature of the air outlet near the PSU.