| Total number of VSRP routers defined
|
The total number of VRIDs configured on this device.
|
| VLAN
|
The VLAN on which VSRP is configured.
|
| auth-type
|
The authentication type in effect on the ports in the VSRP VLAN.
|
| VRID
|
The VRID for which the VSRP information is displayed.
|
| state
|
The device VSRP state for the VRID. The state can be one of the following:
- initialize: The VRID is not enabled (activated). If the state remains "initialize"
after you activate the VRID, make sure that the VRID is also configured on the other
routers and that the routers can communicate with each other.
- standby: This device is a backup for the VRID.
- master: This device is the master for the VRID.
|
| Administrative-status
|
The administrative status of the VRID. The administrative status can be one of the
following:
- disabled: The VRID is configured on the interface but VSRP or VRRP-E has not been
activated on the interface.
- enabled: VSRP has been activated on the interface.
|
| Advertise-backup
|
Whether the device is enabled to send VSRP Hello messages when it is a backup. This
field can have one of the following values:
- disabled: The device does not send Hello messages when it is a backup.
- enabled: The device sends Hello messages when it is a backup.
|
| Preempt-mode
|
Whether the device can be preempted by a device with a higher VSRP priority after
this device becomes the master. This field can have one of the following values:
- disabled: The device cannot be preempted.
- enabled: The device can be preempted.
|
| save-current
|
The source of VSRP timer values preferred when you save the configuration. This field
can have one of the following values:
- false: The timer values configured on this device are saved.
- true: The timer values most recently received from the master are saved instead of
the locally configured values.
|
| Configured
|
Indicates the parameter value configured on this device.
|
| Current
|
Indicates the parameter value received from the master.
|
| Unit
|
Indicates the formula used tor calculating the VSRP priority and the timer scales
in effect for the VSRP timers. A timer true value is the value listed in the Configured
or Current field divided by the scale value.
|
| priority
|
The device preferability for becoming the master for the VRID. During negotiation,
the backup with the highest priority becomes the master. If two or more backups are
tied with the highest priority, the backup interface with the highest IP address becomes
the master for the VRID.
|
| hello-interval
|
The number of seconds between Hello messages from the master to the backups for a
given VRID.
|
| dead-interval
|
The configured value for the dead interval. The dead interval is the number of seconds
a backup waits for a Hello message from the master for the VRID before determining
that the master is no longer active. If the master does not send a Hello message before
the dead interval expires, the backups negotiate (compare priorities) to select a
new master for the VRID. If the value is 0, then you have not configured this parameter.
|
| hold-interval
|
The number of seconds a backup that intends to become the master will wait before
actually beginning to forward Layer 2 traffic for the VRID. If the backup receives
a Hello message with a higher priority than its own before the hold-down interval
expires, the backup remains in the backup state and does not become the new master.
|
| initial-ttl
|
The number of hops a Hello message can traverse after leaving the device before the
Hello message is dropped. A metro ring counts as one hop, regardless of the number
of nodes in the ring.
|
| next hello sent in
|
The amount of time until the master dead interval expires. If the backup does not
receive a Hello message from the master by the time the interval expires, either the
IP address listed for the master will change to the IP address of the new master,
or this Layer 3 switch itself will become the master. This field applies only when
this device is a backup.
|
| Member ports
|
Lists the ports in the VRID. |
| Operational ports
|
Lists the member ports that are currently up. |
| Forwarding ports
|
Lists the member ports that are currently in the forwarding
state. Ports that are forwarding on the master are listed. Ports on
the Standby, which are in the blocking state, are not listed. |
| Restart ports |
Lists the member ports that have VSRP fast start
enabled and displays in parentheses the failover downtime configured
for each port. Only ports that are on the master are listed. If the
device is in the standby state, then “None” is displayed. |