Deploying vSZ on Proxmox Virtual Environment

Deploying vSZ on a Proxmox Virtual Environment (VE) offers several advantages. It has a user-friendly interface, supports various disk formats, is cost-effective as an open-source solution, and provides efficient performance and scalability for both small and large deployments.
To deploy vSZ on a Proxmox VE, follow these steps:
  1. Log in to Proxmox VE and click OK to skip the No valid subscription.
  2. Click Create VM.
    The Create Virtual Machine set-up window opens.

    Creating a Virtual Machine

    Creating a VM
  3. Optionally, in the General tab, you can configure these options:
    1. VM ID: Proxmox assigns VM IDs starting from 100, with each new VM receiving the next sequential ID. You can modify this number, but RUCKUS recommends using the default value.
    2. Name: Enter a descriptive host name.
    3. Resource Pool: Select a resource pool using the drop-down menu.
    4. Click Next.

    Configuring General Settings

    Configuring General Options
  4. In the OS tab, select Do not use any media and click Next.

    Configuring OS Settings

    Configuring OS options
  5. In the System tab, keep the default settings and click Next.

    Configuring System Settings

    Configuring System Options
  6. In the Disks tab, delete the default disk on the left side of the window and click Next.

    Configuring Disks Settings

  7. In the CPU tab, configure these options:
    1. In the Sockets drop-down menu, select 2.
    2. In the Cores drop-down menu, select 2.
    3. In the Type drop-down menu, select kvm64.
    4. Click Next.
  8. Note: You can adjust the number of sockets and cores according to your system needs, but ensure that you select at least 2 sockets and 2 cores. Selection of CPU sockets and cores is based on deployment requirements for vSZ efficiency and reliability, as well as hypervisor hardware capacity. For more information, refer to Virtual SmartZone Deployment Requirements.

    Configuring CPU Settings

    Configuring CPU Settings
  9. In the Memory tab, configure these options:
    1. In the Memory (MiB) drop-down menu, select the required memory. Memory is measured in Mebibytes (MiB). A MiB is equal to 2^20 bytes, or 1,048,576 bytes.
    2. In the Minimum memory (MiB) drop-down menu, select the required minimum memory.
    3. Check the Ballooning Device checkbox.
    4. Click Next.
  10. Note: Selection of memory is based on deployment requirements for vSZ efficiency and reliability, as well as hypervisor hardware capacity. For more information, refer to Virtual SmartZone Deployment Requirements.

    Configuring Memory Settings

    Configuring Memory Settings
  11. In the Network tab, configure these options:
    1. In the Bridge drop-down menu, select the bridge.
    2. In the Model drop-down menu, select VirtIO (paravirtualized).
    3. Uncheck the Firewall checkbox.
    4. Click Next.

      Configuring Network Settings

      Configuring Network Settings
  12. In the Confirm tab, review the settings that you configured and click Finish.
    Important: Do not check the Start after created checkbox. You should verify the configuration, make any necessary changes, and click Finish.

    Reviewing the Settings

    Reviewing the Settings
  13. Download and unzip the vSZ QCOW2 file from https://support.ruckuswireless.com/.
  14. Log in through SSH or use the terminal on Web UI to operate on the command line of the root account.
    Optionally, you can create a temporary directory and place the image in it. For example:
    /var/lib/vz/template/qcow/
  15. Place the QCOW2 image into the Proxmox Hypervisor. Use the following command to import the disk image into the virtual machine:
    Syntax:
    qm importdisk <VM ID> <qcow2 image> <storage name>
    Example :
    qm importdisk 929 ./vscg-7.0.0.0.726.qcow2 local-lvm

    QCOW2 Image

    QCOW2 Image
  16. Add and configure the Unused Disk:
    1. On the Proxmox web UI, click the virtual machine that you created, select Hardware and double-click Unused Disk. Optionally, you can select Unused Disk and click Edit.

      The Add Unused Disk window opens.

      Importing the Disk

      Importing the Disk
    2. Click the Disk tab.
    3. In the Bus/Device drop-down menu, select VirtIO Block.
    4. In the Disk Image drop-down menu, make sure that the disk image is the same disk image that you imported in the previous step.
    5. Click Add.

    Configuring the Disk

    Configuring the Disk
  17. To change the boot order of the virtual machine (VM), follow these steps:
    1. From the web page, select Options and double-click Boot Order. Optionally, you can select Boot Order and click Edit.

      The Edit: Boot Order window opens.

    2. Check the Enabled checkbox for your VM.
    3. Click and hold your left mouse button on the icon, drag your VM to the first entry of the boot order, and release your mouse button to drop the element in the new location.
    4. Click OK.

      Editing the Boot Order

      Editing the Boot Order
  18. From the web page, select the virtual machine, click Start, and select Console.

    Your vSZ boots up and is now ready for use.

    Deploying vSZ on Proxmox VE Successful

    Deploying vSZ on Promox VE Successful
  19. To add additional network devices based on vSZ type, on the web page, select the virtual machine that you created, click Hardware > Add and select the required network device.

Adding Additional Network Devices

Adding Additional Network Devices