show spx pe-port-vlan-resources

Displays VLAN resources per PE port for an SPX (Campus Fabric) system.
Syntax
show spx pe-port-vlan-resources
Modes

All modes

The show spx pe-port-vlan-resources command displays the following information:

Output field Description
Reserved number of VLANs for each PE port 4 (fixed value). Number of VLANs for which each PE port is guaranteed membership.
Maximum number of VLANs a PE port can be added to Maximum allowable VLANs per PE port as configured with the max-vlans-per-pe-port (Valid range is 5 through 1024).
Configured PE VLAN entries Number of VLANs configured for PEs in the SPX system.
PE VLAN Global Pool size 4096. Global pool of available PE port-to-VLAN assignments, not including four VLAN assignments already reserved for each PE port.
Entries used in PE VLAN Global Pool Number of configured entries in the global PE VLAN pool. The number may be oversubscribed.
Entries available in PE VLAN Global Pool From 4096, number of remaining entries in the PE VLAN pool.
Ports with more than reserved number of VLANs Number of PE ports that have more than 4 VLANs configured.
Configuration failures due to hash collisions Number of PE port VLAN configuration rejections due to table space collision at or near maximum scaling.
Examples

The following example shows output for the show spx pe-port-vlan-resources command.

device# show spx pe-port-vlan-resources
PE VLAN Global Pool Resource Usage:
============================================================
Reserved number of VLANs for each PE port : 4
Maximum number of VLANs a PE port can be added to : 1023
Configured PE VLAN entries : 4483
PE VLAN Global Pool size : 4096
Entries used in PE VLAN Global Pool : 4096
Entries available in PE VLAN Global Pool : 0
Ports with more than reserved number of VLANs : 33
Configuration failures due to hash collisions : 0
============================================================
History
Release version Command history
08.0.80 This command was introduced.