event

Updates event notification configurations.
Syntax
event { eventCode | db-persistence | email | snmp-notification }
no event { db-persistence | email | snmp-notification }
Command Default

Event notification configurations are not updated.

Parameters
eventCode
Specifies a specified configuration event notification .
db-persistence
Enables data blade persistence for an event.
email
Enables email notifications.
snmp-notifcation
Enables selected SNMP notifications.
Modes

Global configuration mode

Usage Guidelines

This command is supported on all SmartZone platforms except SmartZone Data Plane controller.

The no form of the command disables configured event notifications.

Examples

The following example enables data blade persistence notifications for an event.

device(config)# event db-persistence

   No. Event Code Category  Type                      Description                       Severity       SNMP      OID                           Email    DB Persistence

   --- ---------- --------- ------------------------- -------------------------------- ------------ -----------  -------------------------- -----------  ----------

   1   101        AP        AP discovery succeeded   This event occurs when AP sends a  Informational  Disabled  1.3.6.1.4.1.25053.2.10.1.46   Enabled   Enabled

                                                     discovery request to the SmartZone                                                  

                                                     successfully.                                                                      

   2   103        AP        AP managed               This event occurs when AP is       Informational  Disabled  1.3.6.1.4.1.25053.2.10.1.41   Disabled  Enabled

                                                     approved by the SmartZone.                                                               

   3   105        AP        AP rejected              This event occurs when AP is       Minor          Enabled   1.3.6.1.4.1.25053.2.10.1.28   Disabled  Enabled

                                                     rejected by the SmartZone.                                                               

   4   106        AP        AP firmware updated      This event occurs when AP         Informational  Disabled   1.3.6.1.4.1.25053.2.10.1.35   Disabled  Enabled

                                                     successfully updates its firmware.                                                          

   5   107        AP        AP firmware update failed  This event occurs when the AP     Major          Enabled  1.3.6.1.4.1.25053.2.10.1.34   Disabled  Enabled

                                                       fails to update its firmware.                                                           

  

The following example enables SNMP notifications for an event.

device(config)# event snmp-notification

   No. Event Code Category    Type                   Description                        Severity       SNMP      OID                         Email    DB Persistence

   --- ----------- ---------  --------------------- ---------------------------------   ----------- ----------  -------------------------- -------- --------------

   1   101        AP          AP discovery succeeded This event occurs when AP sends a  Informational  Disabled  1.3.6.1.4.1.25053.2.10.1.46  Enabled   Enabled

                                                     discovery request to the SmartZone                                                  

                                                     successfully.                                                                      

   2   103        AP          AP managed              This event occurs when AP is      Informational  Disabled   1.3.6.1.4.1.25053.2.10.1.41 Disabled   Enabled

                                                      approved by the SmartZone.                                                               

   3   105        AP          AP rejected             This event occurs when AP is      Minor          Enabled    1.3.6.1.4.1.25053.2.10.1.28 Disabled   Enabled

                                                      rejected by the SmartZone.                                                               

   ...