Fan detection and error checking policies

During system startup and operation, the Brocade ICX 7250, checks the fan status and automatically performs corrective actions and generates syslog messages if a problem is detected (refer to the following table).
Added this topic to 08.0.40 release, per a request from Huzefa Burmawala. Added from 'SICA_THERMAL_POLICY_R2 3.pdf' aka 'BROCADE SICA-24/24P/24G/48/48P Thermal Policy'..

If the Brocade ICX 7250 determines that there is a problem with the fans, it performs the following actions and generates the following syslog messages, as shown in the following table.

Note: To determine the fan direction (either front to back, or back to front), enter the show chassis command.

Brocade ICX 7250 fan error detection and resolution

Issue detected Attempted resolution
During system bootup, no fan is detected The system immediately shuts down.
During system bootup, fewer fans than required for normal operation are detected The system boots up normally and follows the fan speed and shutdown policy as described in Temperature threshold levels. A syslog message is generated that describes the issue.
System boots up normally, but all fans fail during system operation The system immediately shuts down. A syslog message describing the issue is generated prior to shutdown.
After system bootup, fewer fans than required for normal operation are detected No action is performed. The system follows the fan speed and shutdown policy as described in Temperature threshold levels. A syslog message is generated that describes the issue.
After system bootup, two of the power supply fans are detected as operating in opposite directions No action is performed. The system follows the fan speed and shutdown policy as described in Temperature threshold levels. A syslog message is generated that describes the issue.
After system bootup, two of the module fans are detected as operating in opposite directions No action is performed. The system follows the fan speed and shutdown policy as described in Temperature threshold levels. A syslog message is generated that describes the issue.
After system bootup, the power supply and module fans are detected as operating in opposite directions No action is performed. The system follows the fan speed and shutdown policy as described in Temperature threshold levels. A syslog message is generated that describes the issue.
During normal system operation, one of the module fans reports that it is operating in the incorrect direction No action is performed. The system follows the fan speed and shutdown policy as described in Temperature threshold levels. A syslog message is generated that describes the issue.
During normal system operation, the system detects that a power supply or module fan has been replaced, and the new fan is operating in the incorrect direction No action is performed. The system follows the fan speed and shutdown policy as described in Temperature threshold levels. A syslog message is generated that describes the issue.
System detects that the critical (shutdown) temperature has been exceeded The system generates a syslog message when the issue is detected, and every 30 seconds after detection. If the critical (shutdown) temperature is exceeded for two minutes, the system shuts down.