Resolving Module 3 Mismatches in a Standalone RUCKUS ICX 7550 Switch

Use the following procedure to resolve a Module 3 configuration mismatch for a RUCKUS ICX 7550 switch in standalone mode.

  1. Power down the switch, replace the installed module, and then reboot the switch.
  2. Use the no module command to remove the current Module 3 configuration.
    device(config-unit-1)# no module 3 icx7600-xgf-4port-40g-module
      icx7600-100g-1port-100g-module
      icx7600-qsfp-2port-80g-module
      icx7600-xgf-4port-40g-module
    
  3. Configure Module 3 for the installed module.
    device(config-unit-1)# module 3 icx7600-xgf-4port-40g-module
      icx7600-100g-1port-100g-module
      icx7600-qsfp-2port-80g-module
      icx7600-xgf-4port-40g-module
    
  4. Use the write memory command and then check the configuration with the show config command.
    device# sh conf
    !
    Startup-config data location is flash memory
    !
    Startup configuration:
    !
    ver 08.0.95_b1555T243
    !
    stack unit 1
      module 1 icx7550-24p-port-management-module
      module 2 icx7550-qsfp-2port-80g-module
     module 3 icx7600-xgf-4port-40g-module
     stack-port 1/2/1
      stack-port 1/2/2
    !