Resolving Module 3 Mismatches in a RUCKUS ICX 7550 Stack
When a RUCKUS ICX 7550 stack unit
rejoins a stack with a different module type installed as Module 3, a configuration
mismatch
occurs, and the active controller places the stack unit in non-operational mode.
Follow these steps to correct a module configuration mismatch in a RUCKUS ICX 7550 stack.
- Enter the show stack command to confirm
that a unit has become non-operational due to a configuration mismatch. An error
message such as the following is displayed:
device# T=3m26.3: Election, I 4cb1.cd20.29f8 was alone --> active, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1 1, reason: u2: port-up, , Error - configuration mismatch at u2 module 3, config = icx7600-100g-1port-100g-module, but is icx7600-qsfp-2port-80g-module. Please remove u2 and edit config, or delete module config and let it learn.
- Use one of the following options to resolve an
identified configuration mismatch:
- Option 1: Remove the unit from the stack and allow it to rejoin.
- Option 2: Remove the incorrect
module configuration and allow the correct module information to be learned.
Within Option 2, you can choose from the following:
- Option 2a: In global configuration mode, enter
the no stack
unit command followed by the stack number of the offending device.
device(config)# no stack unit 2
The example removes stack unit 2 from the stack and shows the unit rejoining the stack with the correct configuration.
- Option 2b: In stack unit configuration mode for
the non-operational unit, enter the no module 3
command.
device(config)# stack unit 2 device(config-unit-2)#no module 3
- Option 2a: In global configuration mode, enter
the no stack
unit command followed by the stack number of the offending device.
- (Optional) Enter the show module command to verify
that the new configuration for Module 3 has been learned.
device# show module Module Status Ports Starting MAC U1:M1 ICX7550-48F 48-port Management Module OK 48 4cb1.cd20.29f8 U1:M2 ICX7550-100G 2-port 200G Module OK 8 4cb1.cd20.2a29 U1:M3 ICX7600-2X40GQ 2-port 80G Module OK 8 4cb1.cd20.29f8 U2:M1 ICX7550-48ZP POE 48-port Management Module OK 48 c803.f53a.7c46 U2:M2 ICX7550-100G 2-port 200G Module OK 8 c803.f53a.7c77 U2:M3 ICX7600-2X40GQ 2-port 80G Module OK 8 c803.f53a.7c7fThe example displays the updated configuration of Module 3 in stack unit 2 as a 2-port 80-Gbps module.
- (Optional) Enter the show stack command to
confirm that the stack unit has returned to operation.
device# show stack T=11h44m16.0: alone: standalone, D: dynamic cfg, S: static ID Type Role Mac Address Pri State Comment 1 S ICX7550-48F active 4cb1.cd20.29f8 128 local Ready 2 S ICX7550-48ZP standby c803.f53a.7c46 128 remote Ready