System stacking temperature threshold table

This section displays the MIB objects for the fan speed switching temperature threshold values.

Name, OID, and syntax

Access

Description

snAgentTempThreshold2Table

1.3.6.1.4.1.1991.1.1.2.13.4

SYNTAX: SEQUENCE OF SnAgentTempThreshold2Entry

NA

Table to list temperature threshold levels for 3 speeds of fan settings, threshold and warning temperature . Depending on the temperature level, the fans run at different speeds. There are 3 levels of temperature settings for 3 fan speeds (low, high, and shutdown). This table is applicable to only those modules with temperature sensors. For each row, there are 3 temperature threshold values. The 'high' value, if reached, causes the fan to run at the next highest speed; when the temperature reduces to below the 'low' value, the fan runs at the next lowest speed.

snAgentTempThreshold2Entry

1.3.6.1.4.1.1991.1.1.2.13.4.1

SYNTAX: SEQUENCE OF SnAgentTempThreshold2Entry

NA A row in the module temperature threshold table.
snAgentTempThreshold2UnitNum

1.3.6.1.4.1.1991.1.1.2.13.4.1.1

SYNTAX: Integer

NA The unit number in the system for which threshold levels represented by this row are applicable.
snAgentTempThreshold2Rule

1.3.6.1.4.1.1991.1.1.2.13.4.1.2

SYNTAX: Integer

NA The Rule number in the system for which threshold levels represented by this row are applicable.
snAgentTempThreshold2LowValue

1.3.6.1.4.1.1991.1.1.2.13.4.1.3

SYNTAX: Integer

Read-only

The low value for the temperature threshold, below which the fans would need to operate at the next lower speed. Unit of measure is degrees Celsius. This value is not applicable for the 'low' level, as there is no more lower speed.

snAgentTempThreshold2HighValue

1.3.6.1.4.1.1991.1.1.2.13.4.1.4

SYNTAX: Integer

Read-only

The high value for the temperature threshold, above which the fans would need to operate at the next higher speed. If it reaches more than the high threshold value for 'high' level, the module will be shut down.

Unit of measure is degrees Celsius.

snAgentTempThreshold2ShutdownValue

1.3.6.1.4.1.1991.1.1.2.13.4.1.5

SYNTAX: Integer

Read-only

Actual temperature higher than this threshold value will shut down a part of the switch hardware to cool down the system.

Unit of measure is degrees Celsius. Only management module built with temperature sensor hardware is applicable. For those non-applicable management modules, it returns no-such-name.