| snAgentPoePortNumber 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.1 Syntax:InterfaceIndex
|
Read-only
|
The port number in the ifIndex value.
|
| snAgentPoePortControl 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.2 Syntax: Integer
|
Read-create
|
Powers on or off the inline power on a port. If a port does not have inline power
capability, reading this object returns other(1). Valid values are:
- other(1)
- disable(2)
- enable(3)
- enableLegacyDevice(4)
|
| snAgentPoePortWattage 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.3 Syntax: Integer32
|
Read-create
|
Adjusts the inline power wattage. Valid values are
from 1000 through 15400(IEEE802_3AF)/30000(IEEE802_3AT). Unit of
measure is in milliwatts. This object can only be set after
snAgentPoePortControl has been set to “enable(3)” or
“enableLegacyDevice(4)”. If a port does not have inline power
capability, reading this object returns an undefined value.
|
| snAgentPoePortClass 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.4 Syntax: Integer32
|
Read-create
|
Adjusts the inline power class. Valid values are from 0 through 3(IEEE802_3AF)/4(IEEE802_3AT).
This object can only be set after snAgentPoePortControl has been set to “enable(3)”
or “enableLegacyDevice(4)”. If a port does not have inline power capability, reading
this object returns an undefined value.
|
| snAgentPoePortPriority 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.5 Syntax: Integer
|
Read-create
|
Shows the inline power allocation priority for the power device:
- invalid(0) - Not a POE port
- critical(1)
- high(2)
- low(3)
- medium(4)
- other(5)
|
| snAgentPoePortConsumed 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.6 Syntax: Integer32
|
Read-only
|
Amount of inline power consumed by the port. Unit
of measure is in milliwatts.
|
| snAgentPoePortType 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.7 Syntax: DisplayString
|
Read-only
|
Inline power device type: 802.3af, 802.3at, or legacy device.
|
| snAgentPoePortPDClass 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.8 Syntax: Integer32
|
Read-only
|
This is a power device (PD) signature which the
device learns in the process of PD-classification. PD detection and
PD-classification are two steps in powering PD. If the PD is powered
with user power Specification, then the PoE port power limit will be
set based on PD-detected class.
|
| snAgentPoePortPDClassB 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.9 Syntax: Integer32
|
Read-only
|
The second PD class signature of dual signature PD
which the device learns in the process of PD-classification. PD
detection and PD-classification are two steps of powering PD. If PD
is powered without user power specification, then PoE port power
limit will be set based on both PD detected classes. The value
PDClassB is valid for dual signature PD (IEEE 802.3bt module) having
PDClassA and PDClassB. The value is 0, if PD is not dual signature.
|
| snAgentPoePortlldpReqPwr 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.10
|
Read-only
|
Maximum power requested by PD through LLDP in
milliwatts. |
| snAgentPoePortCapability 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.13 Syntax: Integer32
|
Read-only
|
Capability of port. The values are: 0-others, 1-2pair, and 2 - 4pair. |
| snAgentPoePortMax2PairPwr 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.14 Syntax: Integer32
|
Read-only
|
Maximum power supported by 2pair port in milliwatts. |
| snAgentPoePortMax4PairPwr 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.15 Syntax: Integer32
|
Read-only
|
Maximum power supported by 4pair port in milliwatts. |
| snAgentPoePortMode 1.3.6.1.4.1.1991.1.1.2.14.2.2.1.16 Syntax:
Integer
|
Read-only
|
Poe port overdrive mode. The values are: 0-none and 1-overdrive. |