Fanless Mode Support

Fanless mode enables the device to operate with the fans disabled while limiting the PoE budget to 150 Watts. That is, when fanless mode is enabled, the fan speed is set to zero RPM, thus allowing the device to operate silently.

Fanless mode cannot be enabled when dynamic power management is enabled. If the PoE power allocation is more than 150W, PoE load must be reduced by disabling PoE on interfaces manually or by unplugging PoE devices.

An error message is displayed if you attempt to enable fanless mode in dynamic power mode, as shown in the following example.

ICX8200-48P Router# configure terminal
ICX8200-48P Router(config)# chassis fanless all
To enable global fanless mode, disable PoE dynamic power
management feature. "no inline power allocation dynamic all"

Fanless Mode Considerations

Consider the following points when configuring fanless mode.

  • ICX 8100-24P, ICX 8100-48P, ICX 8200-24, ICX 8200-24P, ICX 8200-48, ICX 8200-48P, and ICX 8200-48PF devices support fanless mode.
  • Even if fanless mode is configured on a switch, fans will be turned on temporarily during bootup or reboot and will be turned off after the bootup.
  • In fanless mode operation, if the temperature of the switch goes beyond a maximum limit, the switch reboots. When fanless mode is enabled on an ICX 8200 device with both 1G and 10G SFPs installed, the maximum temperature for the 10G SFP ports is used.
  • When fanless mode is enabled, inserting a 25G SFP will disable the port. If a 25G SFP is already inserted in a port, the optic must be removed before fanless mode can be enabled.

Configuring Fanless Mode and Displaying Status

Fanless mode must be enabled manually. Fanless mode does not depend on the variations in the PoE power allocation and is not triggered based on the thermal policy.

Use the chassis fanless command to enable fanless mode. Use the no chassis fanless command to disable fanless mode. When fanless mode is disabled, the fan speed is reset to auto, and the PoE budget is reinstated to the default value. A system log entry is recorded when fanless mode is enabled or disabled.

Use the show chassis command to check the status of fans and to determine whether the unit is operating in fanless mode.

Example: Adjusting Power before Enabling Fanless Mode

The following example checks PoE power allocation and attempts to configure fanless mode for all fans in an ICX 8200-24P router. A warning message indicates that the power must be adjusted because the unit has more than 150W of PoE power allocated.
ICX8200-24P Router# show chassis 
The stack unit 1 chassis info: 

Power supply 1 (AC - PoE) present, status ok

Fan 1 ok, speed (auto): [[1]]<->2   <--- Fanless mode not enabled
Fan 2 ok, speed (auto): [[1]]<->2

Fan controlled temperature: 39.1 deg-C

Fan speed switching temperature thresholds:
                             Speed 1: NM<----->62       deg-C
                             Speed 2:       54<-----> 69 deg-C (shutdown)

Fan 1 Air Flow Direction:  Front to Back 
Fan 2 Air Flow Direction:  Front to Back 
Slot 1 Current Temperature: 29.7 deg-C (Sensor 1), 31.0 deg-C (Sensor 2), 39.1 deg-C (Sensor 3), 37.0 deg-C (Sensor 4), 40.0 deg-C (Sensor 5)
              Warning level.......: 66.0 deg-C
              Shutdown level......: 69.0 deg-C
Boot Prom MAC : 3845.3b3c.f120
Management MAC: 3845.3b3c.f120
Stack unit-1: The system was last powercycled on Wednesday, 2023-03-15 at 06:08:40+0000 (UTC), powercycle count: 5
ICX8200-24P Router# configure terminal
ICX8200-24P Router(config)# chassis fanless all   <--- Attempt to set all fans to fanless mode  

WARNING: Allocated PoE power (360W) is more than 150W on unit 1, fanless mode
cannot be enabled.To enable fanless mode in unit 1,
kindly turn off PoE on interfaces manually until
allocated PoE power is less than or equal to 150W
Fanless mode disabled in unit(s): None
ICX8200-24P Router(config)#end
The following example turns off inline power on a range of ports to adjust power consumption to the required level. It checks power status, enables fanless mode on all fans in one unit, and checks chassis status.
ICX8200-24P Router# configure terminal  
ICX8200-24P Router(config)# no inline power ethernet 1/1/6 to 1/1/24
ICX8200-24P Router(config)# end

ICX8200-24P Router# show inline power

Power Capacity:         Total is 150000 mWatts. Current Free is 150000 mWatts. <-- max allowed

Power Allocations: Requests Honored 68 times


Port      Admin   Oper    ---Power(mWatts)---  PD Type  PD Class     Pri Fault/
          State   State   Consumed  Allocated                            Error
-----------------------------------------------------------------------------
1/1/1     On      Off         0         0       n/a      n/a          3  n/a
!
!
1/1/16    Off     Off         0         0       n/a      n/a          3  n/a
1/1/17    Off     Off         0         0       n/a      n/a          3  n/a
1/1/18    Off     Off         0         0       n/a      n/a          3  n/a
1/1/19    Off     Off         0         0       n/a      n/a          3  n/a
1/1/20    Off     Off         0         0       n/a      n/a          3  n/a
1/1/21    Off     Off         0         0       n/a      n/a          3  n/a
1/1/22    Off     Off         0         0       n/a      n/a          3  n/a
1/1/23    Off     Off         0         0       n/a      n/a          3  n/a
1/1/24    Off     Off         0         0       n/a      n/a          3  n/a
-----------------------------------------------------------------------------
Total                         0         0

ICX8200-24P Router(config)# chassis fanless all  <--- Fanless mode is enabled for all fans
Fanless mode enabled in unit(s): 1
ICX8200-24P Router(config)# end

ICX8200-24P Router# show chassis 
The stack unit 1 chassis info: 

Power supply 1 (AC - PoE) present, status ok

Fan 1: Fanless mode enabled      <--- Confirms fanless mode is enabled 
Fan 2: Fanless mode enabled 

Fan 1 Air Flow Direction: Fanless mode enabled
Fan 2 Air Flow Direction: Fanless mode enabled
Slot 1 Current Temperature: 30.1 deg-C (Sensor 1), 31.7 deg-C (Sensor 2), 40.1 deg-C (Sensor 3), 38.0 deg-C (Sensor 4), 40.0 deg-C (Sensor 5)
              Warning level.......: 66.0 deg-C
              Shutdown level......: 69.0 deg-C
Boot Prom MAC : 3845.3b3c.f120
Management MAC: 3845.3b3c.f120
Stack unit-1: The system was last powercycled on Wednesday, 2023-03-15 at 06:08:40+0000 (UTC), powercycle count: 5
ICX8200-24P Router#

Example: Disabling 25G Optics before Enabling Fanless Mode

The following example checks media status and attempts to enable fanless mode. A system message indicates the presence of 25G optics, which are incompatible with fanless mode. The user disables the offending ports before successfully enabling fanless mode.
ICX8200-48 Router# show chassis 
The stack unit 1 chassis info: 

Power supply 1 (AC - Regular) present, status ok

Fan ok, speed (auto): [[1]]<->2    <-- Fanless mode not enabled

Fan controlled temperature: 43.8 deg-C

Fan speed switching temperature thresholds:
                             Speed 1: NM<----->61       deg-C
                             Speed 2:       53<-----> 70 deg-C (shutdown)

Fan 1 Air Flow Direction:  Front to Back 
Slot 1 Current Temperature: 32.6 deg-C (Sensor 1), 41.3 deg-C (Sensor 2), 43.8 deg-C (Sensor 3), 49.0 deg-C (Sensor 4)
              Warning level.......: 67.0 deg-C
              Shutdown level......: 70.0 deg-C
Boot Prom MAC : 3845.3b3c.ddee
Management MAC: 3845.3b3c.ddee
Stack unit-1: The system was last powercycled on Monday, 2023-04-17 at 05:53:10+0000 (UTC), powercycle count: 5
ICX8200-48 Router#                                               

ICX8200-48 Router# configure terminal
ICX8200-48 Router(config)# chassis fanless all
To enable fanless mode in unit 1, Please disable 25G ports or remove 25G optics <-- No fanless mode w/ 25G optics

ICX8200-48 Router# show media val

Port       Supported Vendor               Type                                                                            
----------------------------------------------------------------------
1/2/1      Yes       RUCKUS                Type  : 25GBASE-SR 100m (SFP28)                                                
1/2/3      Yes       RUCKUS                Type  : 25GBASE-SR 100m (SFP28) 
 
ICX8200-48 Router# configure terminal
ICX8200-48 Router(config)# internet ethernet 1/2/1 ethernet 1/2/3 <-- Disabling offending ports
ICX8200-48 Router(config-mif-1/2/1,1/2/3)# disable
ICX8200-48 Router(config-mif-1/2/1,1/2/3)# exit

ICX8200-48 Router(config)# chassis fanless all <-- Fanless mode can be enabled now.
Fanless mode enabled in unit(s): 1
ICX8200-48 Router(config)# end
ICX8200-48 Router#

ICX8200-48 Router# show chassis 
The stack unit 1 chassis info: 

Power supply 1 (AC - Regular) present, status ok

Fanless mode enabled

Fan 1 Air Flow Direction: Fanless mode enabled  <-- Fanless mode confirmed.
Slot 1 Current Temperature: 32.7 deg-C (Sensor 1), 41.5 deg-C (Sensor 2), 44.0 deg-C (Sensor 3), 49.0 deg-C (Sensor 4)
              Warning level.......: 67.0 deg-C
              Shutdown level......: 70.0 deg-C
Boot Prom MAC : 3845.3b3c.ddee
Management MAC: 3845.3b3c.ddee
Stack unit-1: The system was last powercycled on Monday, 2023-04-17 at 05:53:10+0000 (UTC), powercycle count: 5