Displaying Information for Breakout Ports

You can use the show breakout command output to display information for breakout port status.

The show breakout command indicates which ports are configured for breakout and which breakout ports are in operation. Refer to the RUCKUS FastIron Command Reference for more information.

The following example displays breakout port information for an ICX 7550-24F device with the slot 2 uplink-100G setting.

device> show breakout
Unit-Id: 1    
Port       Module Exist    Module Conf     breakout_conf   breakout_oper               
1/2/2      Yes             No              Yes             Yes             

The following example displays breakout port information for an ICX 7850-48FS device.

device> show breakout
Unit-Id: 1    
Port       Module Exist    Module Conf     breakout_conf   breakout_oper               
1/2/1      Yes             No              Yes             Yes
1/2/2      Yes             No              No              No
1/2/3      Yes             No              Yes             Yes
1/2/4      Yes             No              No              No
1/2/5      Yes             No              No              No
1/2/6      Yes             No              No              No
1/2/7      Yes             No              No              No
1/2/8      Yes             No              No              No