| snTrapStackingMasterElected brcdIp.0.163
|
snChasUnitIndex,
snAgGblTrapMessage
|
Minor
|
The SNMP trap that is
generated when a unit is elected as the Master unit for the stacking
system.
Sample trap
message:
Stack unit
<unitNumber> has been elected as ACTIVE unit of the stack
system
|
| snTrapStackingUnitAdded brcdIp.0.164
|
snChasUnitIndex,
snAgGblTrapMessage
|
Minor
|
The SNMP trap that is
generated when a unit has been added to the stacking system.
Sample trap
message:
Stack: Stack unit
<unitNumber> has been added to the stack
system
|
| snTrapStackingUnitDeleted brcdIp.0.165
|
snChasUnitIndex,
snAgGblTrapMessage
|
Minor
|
The SNMP trap that is
generated when a unit has been deleted from the stacking system.
Sample trap
message:
Stack: Stack unit
<unitNumber> has been deleted to the stack
system
|
| snTrapStackingChasPwrSupplyOK brcdIp.0.166
|
snChasUnitIndex,
snChasPwrSupplyIndex, snAgGblTrapMessage
|
Minor
|
The SNMP trap that is
generated when a power supply operational status changed from
failure to normal for a stacking system.
Sample trap
message:
System: Stack
unit <unitNumber> Power supply
<snChasPwrSupplyIndex> is up
|
| snTrapStackingChasPwrSupplyFailed brcdIp.0.167
|
snChasUnitIndex,
snChasPwrSupplyIndex, snAgGblTrapMessage
|
Minor
|
The SNMP trap that is
generated when a power supply operational status changed from normal
to failure for a stacking system.
Sample trap
message:
System: Stack
unit <unitNumber> Power supply
<snChasPwrSupplyIndex> is down
|
| snTrapStackingChasFanNormal brcdIp.0.168
|
snChasUnitIndex,
snChasFanIndex, snChasFanDescription
|
Minor
|
The SNMP trap that is
generated when a fan operational status changed from failure to
normal for a stacking system.
Sample trap
message:
System: Stack
unit <unitNumber> Fan <snChasFanIndex>
(<snChasFanDescription>), ok
|
| snTrapStackingChasFanFailed brcdIp.0.169
|
snChasUnitIndex,
snChasFanIndex, snChasFanDescription
|
Minor
|
The SNMP trap that is
generated when a fan fails to operate normally for a stacking
system.
Sample trap
message:
System: Stack
unit <unitNumber> Fan <snChasFanIndex>
(<snChasFanDescription>), failed
|
| snTrapStackingManagementMAC Changed brcdIp.0.170
|
snAgGblTrapMessage
|
Minor
|
The SNMP trap that is
generated when the managemnet MAC address of a stacking system has
been changed.
Sample trap
message:
System:
Management MAC address changed to
<mac_address>
|
| snTrapStackingTemperatureWarning brcdIp.0.171
|
snChasUnitIndex,
snAgGblTrapMessage
|
Minor
|
The SNMP trap that is
generated when the actual temperature reading is above the warning
temperature threshold for a stack sytem.
Sample trap
message:
System: Stack
unit <unitNumber> Temperature <actual-temp> C
degrees, warning level <warning-temp> C degrees, shutdown
level <shutdown-temp> C degrees
|
| snTrapStackingMixedModeChanged brcdIp.0.199
|
snStackingGlobalMixedMode, snAgGblTrapMessage |
Notification
|
The SNMP trap that is generated when a stacking system
mode is changed. |
|
snTrapStackingShowStack Connect
brcdIp.0.209
|
snAgGblTrapMessage
|
Notification
|
The SNMP trap is
generated when the background diagnosis detects the connection
errors to notify the user to check the connections in a stacking
system.
Format:
Background diagnosis detects connection errors. Please use show
stack conn to view detailed connections.
|
|
snTrapStackingStandByChanged Standalone
brcdIp.0.210
|
snChasUnitIndex,
snAgGblTrapMessage
|
Notification
|
The SNMP trap is
generated when a unit is changed from Standby to Standalone when the
active unit is down.
|
snTrapStackISSUSystemCompleted
brcdIp.0.215
|
snAgGblTrapMessage
|
Notification
|
The SNMP trap is generated when system completed stack upgrade process.
|
snTrapStackISSUSystemFailed
brcdIp.0.216
|
snAgGblTrapMessage
|
Alerts
|
The SNMP trap is generated when system failed stack upgrade process.
|
snTrapStackISSUUnitCompleted
brcdIp.0.217
|
snChasUnitIndex, snAgGblTrapMessage
|
Notification
|
The SNMP trap is generated when unit completed upgrade process.
Format: Stack: stack unit
<unit_id> completed upgrade
|
snTrapStackISSUUnitFailed
brcdIp.0.218
|
snChasUnitIndex, snAgGblTrapMessage
|
Alerts
|
The SNMP trap is generated when unit failed upgrade process.
Format: Stack: system upgrade failed, stack unit
<unit_id> is in failure state
|
snTrapStackISSUSystemStart
brcdIp.0.219
|
snAgGblTrapMessage
|
Notification
|
The SNMP trap is generated when system starts stack upgrade process.
Format: Stack: system upgrade started and most of user interfaces are blocked
|
|
snTrapStackingIgnoreShutdown TemperatureThresholdEnabled
brcdIp.0.220
|
snChasUnitIndex
snAgGblTrapMessage
|
Alerts
|
The SNMP trap is
generated when Ignore Shutdown Temperature Threshold is enabled for
a stack unit.
|
|
snTrapStackingIgnoreShutdown TemperatureThresholdDisabled
brcdIp.0.221
|
snChasUnitIndex
snAgGblTrapMessage
|
Alerts
|
"The SNMP trap is
generated when Ignore Shutdown Temperature Threshold is disabled for
a stack unit.
|