System stacking temperature threshold table

This section displays the MIB objects for the fan speed switching temperature threshold values.

Name, OID, and syntax

Access

Description

snAgentTempThreshold2Table

brcdIp.1.1.2.13.4

SYNTAX: SEQUENCE OF SnAgentTempThreshold2Entry

NA

Table to list temperature threshold levels for 3 speeds of fan settings, threshold and warning temperature . Depending on the temperature level, the fans run at diffrent speeds of RPM. There are 3 levels of temperature settings for 3 fan speeds (low, high, shutdown). This table is applicable to only those modules with temperature sensors. For each row, there are 3 temperature threshold values. The high value, if reached causes the fan to run at next high level speed and when it reduces the below the low value, the fan runs at next low speed.

snAgentTempThreshold2Entry

brcdIp.1.1.2.13.4.1

SYNTAX: SEQUENCE OF SnAgentTempThreshold2Entry

NA A row in the module temperature threshold table.
snAgentTempThreshold2UnitNum

brcdIp.1.1.2.13.4.1.1

SYNTAX: Integer

NA The unit number in the system for which threshold levels represented by this row are applicable.
snAgentTempThreshold2Rule

brcdIp.1.1.2.13.4.1.2

SYNTAX: Integer

NA The Rule number in the system for which threshold levels represented by this row are applicable.
snAgentTempThreshold2LowValue

brcdIp.1.1.2.13.4.1.3

SYNTAX: Integer

Read-only

The low value for the temperature threshold, below which the fans would need to operate at the next lower speed. Each unit is degrees Celcius. This value is not applicable for the 'low' level, as there is no more lower speed.

snAgentTempThreshold2HighValue

brcdIp.1.1.2.13.4.1.4

SYNTAX: Integer

Read-only

The high value for the temperature threshold, above which the fans would need to operate at the next higher speed. If it reaches more than thehigh threshold value for 'high' level, the module will be shutdown..

Each unit is degrees Celcius.

snAgentTempThreshold2ShutdownValue

brcdIp.1.1.2.13.4.1.5

SYNTAX: Integer

Read-only

Actual temperature higher than this threshold value will shutdown a partial of the switch hardware to cool down the system.

Each unit is degrees Celcius. Only management module built with temperature sensor hardware is applicable. For those non-applicable management module, it returns no-such-name.