Stacking chassis unit information

The following table manages the temperature for devices that supports the stacking functionality.

Name, OID, and syntax

Access

Description

snChasUnitTable

brcdIp.1.1.1.4.1

None

A table of information for each unit in a stack. Only an active unit is displayed in a table row.

snChasUnitIndex

brcdIp.1.1.1.4.1.1.1

Syntax: Integer32

Read-only

The index to the table.

snChasUnitSerNum

brcdIp.1.1.1.4.1.1.2

Syntax: DisplayString

Read-only

The serial number of the unit. If the serial number is unknown or unavailable, then the value should be a zero length string. There can be up to 128 characters for the serial number.

snChasUnitNumSlots

brcdIp.1.1.1.4.1.1.3

Syntax: Integer32

Read-only

Number of slots of the chassis for each unit.

snChasUnitActualTemperature

brcdIp.1.1.1.4.1.1.4

Syntax: Integer

Read-only

Temperature of the chassis. Each unit is 0.5 Degree Celsius. This object applies only to management modules with temperature sensors in hardware. For management modules without temperature sensors, it returns “no-such-name”.

Values are from -110 through 250 Degree Celsius.

snChasUnitWarningTemperature

brcdIp.1.1.1.4.1.1.5

Syntax: Integer

Read-write

Actual temperature higher than the threshold value triggers the switch to send a temperature warning trap. Each unit is 0.5º Celsius.

This object applies only to management modules with temperature sensors in hardware. For management modules without temperature sensors, it returns “no-such-name”.

Values are from 0 through 250 Degree Celsius.

snChasUnitShutdownTemperature

brcdIp.1.1.1.4.1.1.6

Syntax: Integer

Read-only

Actual temperature higher than the threshold value will shut down a portion of the switch hardware to cool down the system. Each unit is 0.5º Celsius. This object applies only to management modules with temperature sensors in hardware. For management modules without temperature sensors, it returns “no-such-name”.

Values are from 0 through 250 Degree Celsius.

snChasUnitIgnoreShutdownTemperature

brcdIp.1.1.1.4.1.1.8

Syntax: Integer

Read-write

Enables or disables the temperature threshold shutdown (Battleshort mode) on the specific unit. Returns the temperature threshold shutdown (Battleshort mode) status enabled(1) or disabled(0) on the specific unit.

Note: The device allows to enable either global Battleshort mode or unit-specific Battleshort mode at a time, but not for both configurations.

The default value is disabled(0). SNMP WALK and SNMP GET operations of the OID give the default value as zero for the unsupported platforms.

snChasUnitFanless

brcdIp.1.1.1.4.1.1.9

Syntax: Integer

Read-write

Fanless mode can be enabled or disabled on certain FastIron devices.

none (0): Not applicable to the device.

enabled(1): Fanless mode is enabled on the device.

disabled(2): Fanless mode is disabled on the device.

The default value is disabled(2).

Note: Fanless mode is applicable to the ICX7150-24P and ICX7150-48P devices only.