FDP global configuration objects

The following objects are used to configure FDP globally.

Name, OID, and syntax

Access

Description

snFdpGlobal

brcdIp.1.1.3.20.1.3

   
snFdpGlobalRun

brcdIp.1.1.3.20.1.3.1

Syntax: Integer

Read-write

Indicates if the FDP is enabled:

  • false(0) - FDP is disabled. FDP entries in snFdpCacheTable are deleted when FDP is disabled.
  • true(1) - FDP is enabled. Enabling FDP automatically enables CDP globally.

Default: false(0)

snFdpGlobalMessageInterval

brcdIp.1.1.3.20.1.3.2

Syntax: Integer

Read-write

Indicates the interval at which FDP messages are to be generated.

Valid values: 5 - 900 seconds

Default: 60 seconds

snFdpGlobalHoldTime

brcdIp.1.1.3.20.1.3.3

Syntax: Integer

Read-write

Indicates how long the receiving device will hold FDP messages.

Valid values: 10 - 255 seconds

Default: 180 seconds

snFdpGlobalCdpRun

brcdIp.1.1.3.20.1.3.4

Syntax: Integer

Read-write

Shows if the CDP is enabled:

  • false(0) - CDP is disabled. CDP entries in snFdpCacheTable are deleted when FDP is disabled.
  • true(1) - CDP is enabled. Enabling CDP does not automatically enable FDP globally.

Default: false (0)