Image version

The following objects show information about software images in a device. These objects are available in all devices.

Name, OID, and syntax

Access

Description

snAgImgVer

1.3.6.1.4.1.1991.1.1.2.1.11

Syntax: DisplayString

Read-only

Shows the version of the running software. The software image file name is displayed in the following format.

major.minor.maintenance[letters]

It can have up to 32 characters.

snAgFlashImgVer

1.3.6.1.4.1.1991.1.1.2.1.12

Syntax: DisplayString

Read-only

Shows the version of the software image that has been saved in the local storage, such as the flash memory. The software image file name is displayed in the following format:

major.minor.maintenance[letters]

It can have up to 32 characters.

If this file is unknown or not available, then this object displays a null string.

snAgGblIfIpAddr

1.3.6.1.4.1.1991.1.1.2.1.13

Syntax: Integer

Read-write

Shows the IP address of the interface.

snAgGblIfIpMask

1.3.6.1.4.1.1991.1.1.2.1.14

Syntax: Integer

Read-write

Shows the IP address mask of the interface.

snAgGblDataRetrieveMode

1.3.6.1.4.1.1991.1.1.2.1.19

Syntax: Integer

Read-write

Retrieves the VLAN Table and Port-STP Table data as indicated by the selected mode. The mode can be one of the following:

  • nextbootCfg(0) - Retrieves the next boot configuration data.
  • operationalData(1) - Retrieves the current running data.

Default: nextbootCfg(0)

snAgSystemLog

1.3.6.1.4.1.1991.1.1.2.1.20

Syntax: Octet String

Read-write

Indicates whether any network management system has login privileges. The agent allows only one network management system to be logged in.

The value of this object consists of an Octet String. The following four bytes contain a secret code.

The value of the first byte can be one of the following:

  • login(1) - Login for a network management system.
  • heartbeat(2) - A value for the login NMS periodically to check in; otherwise, the Agent automatically sets this object to logout(3) after a timeout period.
  • logout(3) - A value for an NMS to log out.
snAgGblEnableColdStartTrap

1.3.6.1.4.1.1991.1.1.2.1.21

Syntax: Integer

Read-write

Indicates if the SNMP agent process has been enabled to generate cold start traps:

  • disabled(0)
  • enabled(1)

Default: enabled(1)

snAgGblEnableLinkUpTrap

1.3.6.1.4.1.1991.1.1.2.1.22

Syntax: Integer

Read-write

Indicates if the SNMP agent process has been enabled to generate link up traps:

  • disabled(0)
  • enabled(1)

Default: enabled(1)

snAgGblEnableLinkDownTrap

1.3.6.1.4.1.1991.1.1.2.1.23

Syntax: Integer

Read-write

Indicates if the SNMP agent process has been enabled to generate link down traps:

  • disabled(0)
  • enabled(1)

Default: enabled(1)

snAgGblPasswordChangeMode

1.3.6.1.4.1.1991.1.1.2.1.24

Syntax: Integer

Read-only

Specifies which management entity is allowed to change the “enable” password for the device. For security reasons, this object can only be modified using the device CLI.

Valid values:

  • anyMgmtEntity(1) - Any SNMP management station, console command line interface, or Telnet command line interface can be used to change the password.
  • consoleAndTelnet(2) - The password can be changed using the console command line interface or the Telnet command line interface.
  • consoleOnly(3) - Only the console command line interface can be used.
  • telnetOnly(4) - Only the Telnet command line interface can be used.

Default: consoleAndTelnet(2)

snAgGblReadOnlyCommunity

1.3.6.1.4.1.1991.1.1.2.1.25

Syntax: DisplayString

Read-write

Allows you to configure SNMP read-only community strings for the device. This object can be used in an SNMP-Set, but not an SNMP-Get. Get returns a blank.

Valid values: Up to 32 characters

Note: To use this object, make sure that "password-change any" has been configured in the device to allow passwords to be updated from SNMP or any method.
snAgGblReadWriteCommunity

1.3.6.1.4.1.1991.1.1.2.1.26

Syntax: DisplayString

Read-write

Allows you to configure SNMP read-write community strings for the device. This object can be used in an SNMP-Set, but not an SNMP-Get. Get will return a blank.

Valid values: Up to 32 characters.

Note: To use this object, make sure that "password-change any" has been configured in the device to allow passwords to be updated from SNMP or any method.
snAgGblCurrentSecurityLevel

1.3.6.1.4.1.1991.1.1.2.1.27

Syntax: Integer

Read-only

Represents the current login security level (0 through 5). Each level of security requires a password to permit users for different system configurations. Levels are defined in the Image version object.

snAgGblSecurityLevelSet

1.3.6.1.4.1.1991.1.1.2.1.28

Syntax: Integer

Read-write

Shows the security level required to set an “enable” password. This security level can be from 0 through 5.

snAgGblLevelPasswordsMask

1.3.6.1.4.1.1991.1.1.2.1.29

Syntax: Integer32

Read-only

Shows the bitmap of level passwords, which were successfully assigned to the system:

  • Bit 0 - Level 0 = admin
  • Bit 4 - Level 4 = port configuration
  • Bit 5 - Level 5 = read only
snAgGblQueueOverflow

1.3.6.1.4.1.1991.1.1.2.1.30

Syntax: Integer

Read-only

The device queues are overflowing:

  • No(0)
  • Yes(1)
snAgGblBufferShortage

1.3.6.1.4.1.1991.1.1.2.1.31

Syntax: Integer

Read-only

There is a shortage in the device buffers:

  • No(0)
  • Yes(1)
snAgGblDmaFailure

1.3.6.1.4.1.1991.1.1.2.1.32

Syntax: Integer

Read-only

The device DMAs are in good condition:

  • No(0)
  • Yes(1)
snAgGblResourceLowWarning

1.3.6.1.4.1.1991.1.1.2.1.33

Syntax: Integer

Read-only

The device has low resources available:

  • No(0)
  • Yes(1)
snAgGblExcessiveErrorWarning

1.3.6.1.4.1.1991.1.1.2.1.34

Syntax: Integer

Read-only

The device has excessive collision, FCS errors, alignment warnings, and other excessive warnings:

  • No(0)
  • Yes(1)
snAgGblCpuUtilData

1.3.6.1.4.1.1991.1.1.2.1.35

Syntax: Gauge

Read-only

The statistics collection of utilization of the CPU in the devices. Reading this object in the RUCKUS FastIron devices will reset all the counters. Therefore, it is not required to set the object to snAgGblUtilCollect.

snAgGblCpuUtilCollect

1.3.6.1.4.1.1991.1.1.2.1.36

Syntax: Integer

Read-write

Enables or disables the collection of CPU utilization statistics in a device. This can be one of the following:

  • enable(1)
  • disable(0)
snAgGblTelnetTimeout

1.3.6.1.4.1.1991.1.1.2.1.37

Syntax: Integer32

Read-write

Shows how many minutes a Telnet session can remain idle before it times out. Each value unit is one minute. The value of this object can be up to 240 minutes. A value of 0 means that the Telnet session never times out.

snAgGblEnableWebMgmt

1.3.6.1.4.1.1991.1.1.2.1.38

Syntax: Integer

Read-write

Enables or disables access to the device from the Web Management Interface:

  • disable(0)
  • enable(1)
snAgGblSecurityLevelBinding

1.3.6.1.4.1.1991.1.1.2.1.39

Syntax: Integer32

Read-only

After a network management system logs in to a device with a user ID and password, the privilege level assigned to that system is saved in this object. The privilege level can be one of the following:

  • Bit 0 - Level 0 = admin
  • Bit 4 - Level 4 = port configuration
  • Bit 5 - Level 5 = read only
  • 255 - Invalid binding
snAgGblEnableSLB

1.3.6.1.4.1.1991.1.1.2.1.40

Syntax: Integer

Read-only

Enables or disables Server Load Balancing:

  • disable(0)
  • enable(1)
snAgSoftwareFeature

1.3.6.1.4.1.1991.1.1.2.1.41

Syntax: Octet String

Read-only

Contains a bit string representing the software feature of the running software image. Each bit can have one of the following values:

  • 0 - The feature is not available
  • 1 - The feature is available

Bit 0 is the least significant bit of an octet, and bit 7 is the most significant bit of an octet:

  • Octet 0, bit 0 - RMON
  • Octet 0, bit 1 - IPX switching
  • Octet 0, bit 2 - Server Load Balancing
  • Octet 0, bit 3 - Layer 3 filter in switch
  • Octet 0, bit 4 - IPX routing
  • Octet 0, bit 6 - IP multicast routing
  • Octet 0, bit 7 - Local access control
  • Octet 1, bit 0 - BGP routing
  • Octet 1, bit 1 - Loopback interface
  • Octet 1, bit 2 - BigIron multi-management module
  • Octet 1, bit 3 - BigIron SYSIF II
  • Octet 1, bit 4 - BigIron POS support
  • Octet 1, bit 6 - 64 subnet
  • Octet 1, bit 7 - multi-slot trunk
  • Octet 2, bit 0 - TACACS
  • Octet 2, bit 1 - Gigabit Ethernet port auto-negotiation mode
  • Octet 2, bit 3 - Exodus requested OSPF enhancement
  • Octet 2, bit 4 - OSPF NSSA
  • Octet 2, bit 5 - POS
  • Octet 2, bit 6 - QoS
  • Octet 2, bit 7 - Single Span
   
  • Octet 3, bit 0 - Fast Span
  • Octet 3, bit 1 - Base Layer 3
  • Octet 3, bit 2 - Static log buffer
  • Octet 3, bit 3 - Layer 2 POS
  • Octet 3, bit 4 - BI15K
  • Octet 3, bit 5 - Layer 2 ATM
  • Octet 3, bit 6 - ATM
  • Octet 3, bit 7 - NETFLOW
  • Octet 4, bit 0 - sFlow
  • Octet 4, bit 1 - GVRP
  • Octet 4, bit 2 - GARP
  • Octet 4, bit 3 - Dynamic trunk
  • Octet 4, bit 4 - IGC 8G
  • Octet 4, bit 5 - Rate limit
  • Octet 4, bit 6 - IPC rate limit
  • Octet 4, bit 7 - MPLS
  • Octet 5, bit 0 - IS-IS
  • Octet 5, bit 1 - Link aggregation
  • Octet 5, bit 2 - Port dual mode
  • Octet 5, bit 3 - Private VLAN
  • Octet 5, bit 4 - MBGP
  • Octet 5, bit 5 - IPV6 protocol VLAN
  • Octet 5, bit 6 - X10G
  • Octet 5, bit 7 - FastIron Edge switch/router
  • Octet 6, bit 0 - FDP
  • Octet 6, bit 1 - Port tag
  • Octet 6, bit 3 - snSwPortVlanId object has changed from read-only to read-write
  • Octet 6, bit 4 - LLDP

Additional bits are added for new features. Check the MIB file for the software version you are running.

snAgGblEnableModuleInsertedTrap

1.3.6.1.4.1.1991.1.1.2.1.42

Syntax: Integer

Read-write

Indicates if the SNMP agent process has been enabled to generate traps for hardware modules that have been inserted in the chassis:

  • disabled(0)
  • enabled(1)

Default: enabled(1)

snAgGblEnableModuleRemovedTrap

1.3.6.1.4.1.1991.1.1.2.1.43

Syntax: Integer

Read-write

Indicates if the SNMP agent process has been enabled to generate traps for hardware modules that have been removed from the chassis:

  • disabled(0)
  • enabled(1)

Default: enabled(1)

snAgGblEnableTelnetServer

1.3.6.1.4.1.1991.1.1.2.1.45

Syntax: Integer

Read-write

Enables or disables the Telnet server in a device:

  • disable(0)
  • enable(1)

Default: enable(1)

snAgGblTelnetPassword

1.3.6.1.4.1.1991.1.1.2.1.46

Syntax: DisplayString

Read-write

Contains the Telnet access password, which is only used with an SNMP-Set. An SNMP-Get produces a zero string. This object can have 48 characters.

snAgBuildDate

1.3.6.1.4.1.1991.1.1.2.1.47

Syntax: DisplayString

Read-only

Shows the date when the software was built. It can display up to 32 characters.

snAgBuildtime

1.3.6.1.4.1.1991.1.1.2.1.48

Syntax: DisplayString

Read-only

Shows the time when the software was built. It can display up to 32 characters.

snAgBuildVer

1.3.6.1.4.1.1991.1.1.2.1.49

Syntax: DisplayString

Read-only

Shows the image label of the software.

It can display up to 32 characters.

snAgGblCpuUtil1SecAvg

1.3.6.1.4.1.1991.1.1.2.1.50

Syntax: Gauge32

Read-only

Shows CPU utilization every second.

Use snAgentCpuUtilTable on the devices.

snAgGblCpuUtil5SecAvg

1.3.6.1.4.1.1991.1.1.2.1.51

Syntax: Gauge32

Read-only

Shows CPU utilization every five seconds.

Use snAgentCpuUtilTable on the devices.

snAgGblCpuUtil1MinAvg

1.3.6.1.4.1.1991.1.1.2.1.52

Syntax: Gauge32

Read-only

Shows CPU utilization every minute.

Use snAgentCpuUtilTable on the devices.

snAgGblDynMemUtil

1.3.6.1.4.1.1991.1.1.2.1.53

Syntax: Gauge32

Read-only

Shows the system dynamic memory utilization of the device in percentage units.

snAgGblDynMemTotal

1.3.6.1.4.1.1991.1.1.2.1.54

Syntax: Guage32

Read-only

Shows the total amount of system dynamic memory available in a device in number of bytes.

snAgGblDynMemFree

1.3.6.1.4.1.1991.1.1.2.1.55

Syntax: Gauge32

Read-only

Shows the amount of system dynamic memory that is currently available in a device in number of bytes.

snAgTrapHoldTime

1.3.6.1.4.1.1991.1.1.2.1.58

Syntax: Integer

Read-write

The number of seconds that traps will be held during device initialization. Traps are buffered while the device is initialized; they are sent when the device is back online.

Valid value: 1 - 600

snAgSFlowSourceInterface

1.3.6.1.4.1.1991.1.1.2.1.59

Syntax: InterfaceIndex

Read-write

Identifies the source interface for sFlow packets sent by the device that is running sFlow Export.

Use the ifIndex value for this object to specify the source interface to be used. The interface should have an IP address configured for sFlow. A value of zero (0) indicates that a source interface has not been configured for sFlow. Port 65534 is used to specify a null port.

snAgGblTelnetLoginTimeout

1.3.6.1.4.1.1991.1.1.2.1.60

Syntax: Integer

Read-write

Indicates how many minutes you have to log in before Telnet is disconnected.

Valid values: 1 - 10 minutes

Default: 1 minute

snAgGblBannerExec

1.3.6.1.4.1.1991.1.1.2.1.61

Syntax: DisplayString

Read-write

Enter a message that will be displayed when a user enters the Privileged EXEC CLI level of a device.

Enter up to 1270 characters for this banner and the remaining is truncated. Use the character "\n" within the string to start a new line.

Leave this object blank if no message is to be displayed.

snAgGblBannerMotd

1.3.6.1.4.1.1991.1.1.2.1.63

Syntax: DisplayString

Read-write

Enter the message of the day that is displayed on a user’s terminal when the user establishes a Telnet CLI session.

Enter up to 1270 characters for this banner and the remaining is truncated. Use the character "\n" within the string to start a new line.

Leave this object blank if no message is to be displayed.

When performing SNMP operations such as Walk, GET, or GET-Next on the snAgGblBannerMotd object, the banner length returned is now limited to 1500 characters. This is to avoid dependency on the Maximum Transmission Unit (MTU) limit.

snAgWebMgmtServerTcpPort

1.3.6.1.4.1.1991.1.1.2.1.64

Syntax: Integer

Read-write

This object allows you to specify which TCP port will be used for the Web Management Interface.

Enter a number from 1 through 65535.