System temperature table

This section displays the SNMP MIB objects for temperature readings on the RUCKUSFastIron devices.

For stacking devices, refer to System stacking temperature table. The system temperature table shows temperature reading information for each module’s temperature sensor.

Name, OID, and syntax

Access

Description

snAgentTempTable

brcdIp.1.1.2.13.1

None

The table that displays the temperature reading for each module’s temperature sensor. Note that temperature readings are displayed only for those modules that have temperature sensors.

snAgentTempSlotNum

brcdIp.1.1.2.13.1.1.1

Syntax: Integer32

None

The slot number of the module to which the temperature sensor is attached.

snAgentTempSensorId

brcdIp.1.1.2.13.1.1.2

Syntax: Integer32

None

The identification number of the module’s temperature sensor.

The number of temperature sensors vary by switch model.

snAgentTempSensorDescr

brcdIp.1.1.2.13.1.1.3

Syntax: Display string

Read-only

The description of the temperature sensor.

snAgentTempValue

brcdIp.1.1.2.13.1.1.4

Syntax: Integer

Read-only

The temperature reading for the temperature sensor. This value is displayed in units of 0.5º Celsius.