This section displays the SNMP MIB objects for temperature readings on the
RUCKUSFastIron devices.
For stacking devices, refer to
System stacking temperature table. The system temperature table shows temperature reading information for each module’s
temperature sensor.
Name, OID, and syntax
|
Access
|
Description
|
| snAgentTempTable
brcdIp.1.1.2.13.1
|
None
|
The table that displays the temperature reading for each module’s temperature sensor.
Note that temperature readings are displayed only for those modules that have temperature
sensors.
|
| snAgentTempSlotNum
brcdIp.1.1.2.13.1.1.1
Syntax: Integer32
|
None
|
The slot number of the module to which the temperature sensor is attached.
|
| snAgentTempSensorId
brcdIp.1.1.2.13.1.1.2
Syntax: Integer32
|
None
|
The identification number of the module’s temperature sensor.
The number of temperature sensors vary by switch model.
|
| snAgentTempSensorDescr
brcdIp.1.1.2.13.1.1.3
Syntax: Display string
|
Read-only
|
The description of the temperature sensor.
|
| snAgentTempValue
brcdIp.1.1.2.13.1.1.4
Syntax: Integer
|
Read-only
|
The temperature reading for the temperature sensor. This value is displayed in units
of 0.5º Celsius.
|