Fan status

Name, OID, and syntax

Access

Description

snChasEnablePwrSupplyTrap

brcdIp.1.1.1.1.12

Syntax: Integer

Read-write

Indicates if the SNMP agent process has been enabled to generate power supply failure traps:

  • disabled(0)
  • enabled(1)

Default: enabled(1)

snChasMainBrdId

brcdIp.1.1.1.1.13

Syntax: Octet String

Read-only

Applies to all stackable products. It identifies the main board. This is an encoded octet string. Each octet provides the following information:

Octet 0 - Identifies the format of this octet string.

Octets 1 and 2:

If Octet 0 has a value of 1, then:

Octet 1 - Product type:

  • FIWG - 0x57
  • FIBB - 0x42
  • FIMLS - 0x4D
  • TI - 0x54
  • TIRT - 0x52

Octet 2 - Board type:

  • POWERPC - 1
  • ALPHA - 2

The length of the octet string is 27.

If Octet 0 has a value of 2, then:

Octet 1 - Product type:

  • BI_WG - 0x57
  • BI_BB - 0x42
  • NI_M4 - 0x4D
  • BI_SLB - 0x53

Octet 2 - Module type:

   
  • MASTER_FIBER_8G - 0x0
  • MASTER_FIBER_4G - 0x1
  • MASTER_COPPER_16 - 0x2
  • FI_MASTER_FIBER_2G - 0x4
  • FI_MASTER_FIBER_4G - 0x5
  • MASTER_COPPER_8G - 0x6
  • FI_MASTER_FIBER_8G - 0x7
  • MASTER_COPPER_12_2 - 0x9
  • MASTER_FIBER_2G - 0x12
  • MASTER_FIBER_0G - 0x14
  • FI_MASTER_COPPER_8G - 0x1D
  • FI_MASTER_COPPER_4G - 0x1F
  • FI_MASTER_COPPER_2G - 0x20
  • MASTER_COPPER_4G - 0x21
  • MASTER_COPPER_2G - 0x22
  • MASTER_M4_8G - 0x23
  • MASTER_M4_4G - 0x24
  • MASTER_M4_0G - 0x26

The length of the octet string is 28.

   

Octet 3 - Processor type (both format version 1 and 2):

  • PVR_M603 - 3
  • PVR_M604 - 4
  • PVR_M603E - 6
  • PVR_M603EV - 7
  • PVR_M604E - 9

Octet 4 to Octet 5 - Processor speed in MHz (both format version 1 and 2)

Octet 6 - MAC type:

  • MAC_NONE - 0
  • MAC_SEEQ_10_100 - 1
  • MAC_DEC_10_100 - 2
  • PHY_ICS - 3
  • MAC_XI0GMAC_1000 - 4
  • MAC_SEEQ_1000 - 5
  • MAC_GMAC_1000 - 6
  • MAC_VLSI_1000 - 7

Octet 7 - PHY type (both format version 1 and 2):

  • PHY_NONE - 0
  • PHY_QSI - 1
  • PHY_BROADCOM - 2
  • PHY_ICS - 3
  • PHY_NATIONAL - 4
  • PHY_LEVEL1 - 6
  • PHY_LEVEL16 - 7
  • PHY_LEVEL24 - 8
   

Octet 8 - Port type:

  • COPPER - 0
  • FIBER - 1

Octet 9 - Fiber port type (both format version 1 and 2):

  • NONFIBER - 0
  • SX_FIBER - 1
  • LX_FIBER - 2
  • LHX_FIBER - 3
  • LX_SX_FIBER - 4
  • LHB_FIBER - 5

Octet 10 to Octet 13 - DRAM size in KBytes (both format version 1 and 2)

Octet 14 to Octet 17 - Boot flash size in KBytes (both format version 1 and 2)

Octet 18 to Octet 21 - Code flash size in KBytes (both format version 1 and 2)

Octet 22 to Octet 27 - Serial number (both format version 1 and 2)

Octet 28 - Chassis backplane type (format version 1 only):

This octet applies only if Octet 0 is equal to 1.

  • chassis4000 - 0x00
  • chassis8000 - 0x04
  • chassis15000 - 0x05
  • Turbo8 - 0x07 (stack2)
  • FastIron2 - 0x06 (stack1)
snChasEnableFanTrap

brcdIp.1.1.1.1.16

Syntax: Integer

Read-write

For chassis devices only.

Indicates if the SNMP agent process has been enabled to generate fan failure traps:

  • disabled(0)
  • enabled(1)

Default: enabled(1)

snChasIdNumber

brcdIp.1.1.1.1.17

Syntax: DisplayString

Read-only

Shows the chassis identity number. This is used by inventory control. This is not the number on the label of the device.

By default, this object displays a null string. This object can have up to 64 characters.

snChasActualTemperature

brcdIp.1.1.1.1.18

Syntax: Integer

Read-only

Temperature of the chassis. Each unit is 0.5 degrees Celcius.Only management module built with temperature sensor hardwareis applicable. For those non-applicable management module, itreturns no-such-name.
snChasWarningTemperature

brcdIp.1.1.1.1.19

Syntax: Integer

Read-write

Actual temperature higher than this threshold value will trigger the switch to send a temperature warning trap. Each unit is 0.5 degrees Celcius. Only management module built with temperature sensor hardware is applicable. For those non-applicable management module, it returns no-such-name.
snChasShutdownTemperature

brcdIp.1.1.1.1.20

Syntax: Integer

Read-write

Actual temperature higher than this threshold value will shutdown a partial of the switch hardware to cool down the system. Each unit is 0.5 degrees Celcius. Only management module built with temperature sensor hardware is applicable. For those non-applicable management module, it returns no-such-name.
snChasEnableTempWarnTrap

brcdIp.1.1.1.1.21

Syntax: Integer

Read-write

Indicates if the SNMP agent process has been enabled to generate temperature warning traps:

  • disabled(0)
  • enabled(1)

Default: enabled(1)