rmon alarm
rmon alarm
alarm-num
mib-object
sample-interval
{
absolute
|
delta
}
falling-threshold
falling-threshold-value
event
rising-threshold
rising-threshold-value
event
owner
alarm-owner
no rmon alarm
alarm-num
mib-object
sample-interval
{
absolute
|
delta
}
falling-threshold
falling-threshold-value
event
rising-threshold
rising-threshold-value
event
owner
alarm-owner
An RMON alarm is not configured.
- falling-threshold-value
- Specifies the faliing threshold value. The value can range from 0 to 2147483647.
- event
- Specifies the action (event) to take to fire when the falling threshold crosses the configured value. The value can range from 1 through 65535.
- event
- Specifies the event to fire when the rising threshold crosses the configured value. The value can range from 1 through 65535.
Global configuration mode
An Alarm is designed to monitor configured thresholds for any SNMP integer, time tick, gauge, or counter MIB object. Using the CLI, you can define what MIB objects are monitored, the type of thresholds that are monitored (falling, rising, or both), the value of those thresholds, and the sample type (absolute or delta).
An alarm event is reported each time that a threshold is exceeded. The alarm entry also indicates the action (event) to be taken if the threshold be exceeded.
You can configure both the falling threshold and the rising threshold and in any order.
The
no form of the command removes the configured RMON alarm.