remote-loopback
Remote loopback is not initiated on a remote device.
EFM-OAM protocol configuration mode
The
remote-loopback ethernet
stackid/slot/port
{
start
|
stop
}
command is valid only on the Data Terminal Equipment (DTE) operating in the active
mode.
When the remote loopback mode is enabled, all the non-OAMPDUs are looped back at the remote end.
A port ceases to be in the remote loopback mode if any event triggers a change in the port status (up or down).
If EEE is enabled globally, port ceases to be in the remote loopback mode.
Ethernet loopback and EFM-OAM remote loopback cannot be configured on the same interface.
The following example initiates the remote loopback procedure on a remote DTE.
device(config)# link-oam device(config-link-oam)# remote-loopback ethernet 3/1/1 start
| Release version | Command history |
|---|---|
| 08.0.30 | This command was introduced. |