{produce.short.name} failed to connect to LS

{produce.short.name} failed to connect to LS alarm

Alarm

{produce.short.name} failed to connect to LS

Alarm Type

scgLBSConnectFailed

Alarm Code

724

Severity

Major

Aggregation Policy

From the event code 724 an alarm is raised for every event. A single event triggers a single alarm.

Auto Clearance

The alarm is auto cleared with the event code 723.

Attribute

“ctrlBladeMac”=“xx:xx:xx:xx:xx:xx”, “url”=““, “port”=““, “SCGMgmtIp”=““

Displayed on the SmartZone web interface

{produce.short.name} [{SCGMgmtIp}] connection failed to LS: url=[{url}], port=[{port}]

Description

This alarm is triggered when the controller fails to connect to the location based service.

Recommended Actions

Check the location service configuration. Also check the network connectivity between the controller and location server.