Cluster backup failed

Cluster backup failed alarm

Alarm

Cluster backup failed

Alarm Type

backupClusterFailed

Alarm Code

805

Severity

Major

Aggregation Policy

From the event code 810 an alarm is raised for every event. A single event triggers a single alarm.

Auto Clearance

The alarm code is auto cleared with the event code 809.

Attribute

“clusterName”=”xxx”

Displayed on the web interface

Cluster [{clusterName}] backup failed. Reason:[{reason}].

Description

This alarm is triggered when a cluster backup fails.

Recommended Actions

Check the disk usage. Try restoring the communication between nodes for a few more times. If the backup continues to fail or if you encounter Python script errors, please collect the complete system log files (stored in the path - 
/opt/ ruckuswireless/controller/log/system to RUCKUS support for analysis. Possible causes:

  • Insufficient disk space.
  • Communication between nodes may be broken.
  • Errors due to the underlying Python script.