AP Account Message Drop While No Accounting Start Message

Note: This alarm is supported on the SmartZone 300 controllers only. This alarm is not applicable for vSZ-H.

AP Account Message Drop While No Accounting Start Message Alarm

Alarm

AP account message drop while no accounting start message

Alarm Type

apAcctMsgDropNoAcctStartMsg

Alarm Code

1910

Severity

Critical

Aggregation Policy

From the event code 1910 an alarm is raised for every event. A single event triggers a single alarm.

Attribute

“mvnoId”=”12”, “wlanId”=”1”, “zoneId”=”10”,

“ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”aut”,

“realm”=”wlan.3gppnetwork.org",

Displayed on the web interface

[{srcProcess}] Dropped Accounting Packet received from AP [{apIpAddress}] on {produce.short.name} [{SCGMgmtIp}], with username [{userName}]. Accounting session timer expired, stop or interim message not received, as Account Start not received from NAS/AP

Description

This alarm is raised when accounting messages from the AP is dropped. The attributes Acct Interim/Stop message as account start is not received from the AP.

Recommended Action

Check the accounting retransmit timer and retransmit count in the Access Point (AP) configuration. Also check if the interface from the AP to the controller is congested.