PDNGW version not supported

Note: This alarm is supported on the SmartZone 300 controllers only. This alarm is not applicable for vSZ-H.

PDNGW version not supported alarm

Alarm

PDNGW version not supported

Alarm Type

pdnGwVersionNotSupportedMsgReceived

Alarm Code

1952

Severity

Major

Aggregation Policy

From the event code 1952 an alarm is raised for every event. A single event triggers a single alarm.

Attribute

“ctrlBladeMac”=”aa:bb:cc:dd:ee:ff” “srcProcess”=”sm_process” “realm”= ”NA" “gtpcIp”=”5.5.5.5” “pgwIp”=”1.1.1.1” "SCGMgmtIp"="2.2.2.2"

Displayed on the web interface

[{srcProcess}] Version not supported message received from PDN GW with IP [{pgwIp}] on {produce.short.name} [{SCGMgmtIp}].

Description

This alarm is triggered when the version is not supported for messages received from PDN GW.

Recommended Actions

Verify and correct the GPRS tunneling protocol (GTP) version supported in the PGW is GTPv1 and GTPv2.