Unauthorized CoA/DM message dropped

Note: This alarm is supported on the SmartZone 300 controllers only. This alarm is not applicable for vSZ-H.

Unauthorized CoA/DM message dropped alarm

Alarm

Unauthorized CoA/DM message dropped

Alarm Type

unauthorizedCoaDmMessageDropped

Alarm Code

1911

Severity

Critical

Aggregation Policy

From the event code 1911 an alarm is raised for every event. A single event triggers a single alarm.

Attribute

“mvnoId”=”12” “wlanId”=”1” “zoneId”=”10” “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff” “srcProcess”=”aut” “radSrvrIp”=”7.7.7.7” "SCGMgmtIp"="2.2.2.2"

Displayed on the web interface

[{srcProcess}] Dropped CoA/DM Packet received from AAA [{radSrvrIp}] on {produce.short.name} [{SCGMgmtIp}], Received message from unauthorized AAA

Description

This alarm is triggered when the controller receives a Change of Authorization (CoA) or Dynamic Multipoint (DM) message from an unauthorized AAA server.

Recommended Action

Check the RADIUS configuration server settings in the RADIUS service profile. Check if the AAA server is authorized to send the change of authorization (CoA) or dynamic multipoint (DM) messages. If it is authorized, include for RADIUS server to send CoA/DM message in RADIUS service.