Associated PDNGW down

Note: This alarm is supported on the SmartZone 300 controllers only. This alarm is not applicable for vSZ-H.

Associated PDNGW down alarm

Alarm

Associated PDNGW down

Alarm Type

pdnGwAssociationDown

Alarm Code

1953

Severity

Critical

Aggregation Policy

From the event code 1953 an alarm is raised for every event. A single event triggers a single alarm.

Attribute

“ctrlBladeMac”=”aa:bb:cc:dd:ee:ff” “srcProcess”=”sm_process” “realm”= ”NA" “gtpcIp”=”5.5.5.5” “pgwIp”=”1.1.1.1” "SCGMgmtIp"="2.2.2.2"

Displayed on the web interface

[{srcProcess}] Association with PDN GW with IP [{pgwIp}] from {produce.short.name} [{SCGMgmtIp}] down

Description

This alarm is triggered when the association with PDN GW is down due to echo request time out or it fails to send messages to PDN GW.

Recommended Actions

Check the interface from the controller to PDN GW in the web interface to ensure it is reachable.