Accounting Failed Over to Secondary

Note: This alarm is supported on the SmartZone 300 controllers only. This alarm is not applicable for vSZ-H.

Accounting Failed Over to Secondary Alarm

Alarm

Accounting failed over to secondary

Alarm Type

accFailedOverToSecondary

Alarm Code

1653

Severity

Major

Aggregation Policy

An alarm is raised for every event from the event code 1653. A single event triggers a single alarm.

Attribute

“mvnoId”=12 “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff” “srcProcess”=”radiusd” “realm”= ”wlan.mnc080.mcc405.3gppnetwork.org" “radProxyIp”=”7.7.7.7” “primary"=”20.20.20.20” “secondary”=”30.30.30.30”

Displayed on the web interface

Radius Server Failed Over from Primary [{primary}] to Secondary [{secondary}] on Radius Proxy [7.7.7.7] on SCG[2.2.2.2]

Description

This alarm is triggered when the secondary accounting RADIUS server is available after the primary server becomes zombie or dead.

Recommended Actions

No action is required.